Press the "°C/°F" button to set the temperature: each time you
press, 1° is added. Keep the button pressed to go faster.
From 70°C (158°F), the device jumps to -50°C (-58°F).
When you have set the maximum temperature, press the
"Alert/Set" button again to select the 'IN' temperature reading,
which is the minimum value.
Press the "°C/°F" button again to set the temperature.
When the minimum temperature is set, press the "Alert/Set"
button again to exit the alert temperature setting. The alert
function is now ON.
Press the "Alert/Set" button to toggle between ON and OFF. When
the alert function is on, the device will emit 4 sound signals every
30 seconds when either the device itself or the probe is measuring
a temperature outside the set range. This function makes the
device suitable for e.g. frost or overheating monitoring.
Max/min button: Press once to display the maximum in- and
outdoor readings since the last reset; press again to display the
minimum in- and outdoor readings since the last reset; press
again to display the current readings.
Reset button: press this button to reset the memorized maximum
and minimum values and the alert values.
5.
Technical Specifications
power supply
temperature range device: -10~50°C (14~122°F)
resolution/accuracy
dimensions
display size/digit height
Use this device with original accessories only. Velleman nv
cannot be held responsible in the event of damage or injury
resulting from (incorrect) use of this device. For more info
concerning this product and the latest version of this manual,
please visit our website www.velleman.eu. The information in
this manual is subject to change without prior notice.
V. 02 – 26/03/2013
TA20
1 x AAA battery
probe: -50~70°C (-58~158°F)
0.1°/±1°C (1.8°F)
110 x 70 x 20mm
30 x 40mm/12mm
3
©Velleman nv