Utilisation examples
Cable network
Setting of the regulators is
possible with a srew driver
(max. 5 x 0.7 mm) through the
openings on the side panel or
bottom panel.
Cable network
Mounting
Attention:
The units have current-conveying contacts! Do not open! Must only be opened
in the repair department!
Observe the mounting positions and the min. distances needed for heat dissipation (see graph)
Do not install on easily inflammable material.
Admis. ambient temperature at place of installation: -20°C to -55°C.
Only suitable for indoor wall mounting (on even base).
To be fasted with 2 screws. Diam. of screws: 4.5 mm max.
Ground the amplifiers as required.
Connect the cables in conformity with the amplifiers´ use (see examples).
Attention! Admis. diameter of the centre conductor of the connection cables 0.6 to 1.2 mm, free from burr.
We recommend to use the Kathrein cables LCD 90, LCD 95 and LCD 99.
Observe the safety instructions acc. to EN 50083-1 and EN 60065 .
KATHREIN-Werke KG · Anton-Kathrein-Straße 1–3 · Postfach 10 04 44 · D-83004 Rosenheim · Deutschland · Telefon (0 80 31) 18 40 · Telefax (0 80 31) 18 43 06
House connection unit
–– >
–– >
House connection unit
VOS 20/F
4–30 MHz (VOS 20/FR)
4–65 MHz (VOS 20/FB)
VOS 20/FR
VOS 20/FB