OPERATION
Built in Electrical Safety
For your safety and protection this appliance is manufactured with a grounded
plug on its power cord. The power cord must be plugged into a properly ground-
ed receptacle. If a grounded receptacle does not exist, have one installed by a
certified electrician. Do not cut or remove the grounding prong on the power
cord plug if equipped. We recommend that this electrical circuit/ receptacle
operate under a separate breaker or fuse.
Recommended Limits of Use
Temperatures: 0 to 35ºC (32º to 95ºF).
Relative humidity: 20 to 80%.
Location of Unit
Minimum 25cm (10") distance from walls. Close all doors and windows.
25cm
(10")

Initial Start-up

Check the rating plate for the appropriate power supply needed by your unit.
Connect the dehumidifier. Ensure that one of the water collection options is work-
ing and active. Depress the ON switch.
Control Panel Settings
C
D
(A) ON/OFF Switch
Depress the switch to start or stop the dehumidifier. "O" for power off, "I" for
power on.
(B) Hour Counter
The counter will accumulate and display the total running hours of the unit in
1/100 of an hour. It can not be reset to zero. No user input is required.
2
(C) Pump Purge: (Green button - some models)
Depressing this button activates the condensate pump. This can be used to
empty the pump reservoir. The button must be held depressed until drain line
is clear of water, this is when pump reservoir is empty. The dehumidifier must
be switched "ON".
NOTE: Depress the switch long enough to perform the function. Prolonged
depression of the switches could harm the equipment.
(D) Hot Gas On Demand: (Red button - some models)
Depressing this button activates the hot gas defrost system. This can be used
to clear the evaporator coil of frost if required. The button must be held
depressed until the evaporator coil is cleared of frost. The dehumidifier must
be switched "ON".
NOTE: Depress the switch long enough to perform the function. Prolonged
depression of the switches could harm the equipment.
Automatic Defrost Cycle
All units are equipped with an automatically activated (thermostat controlled)
Defrost cycle to automatically defrost the evaporator coils.
Cleaning
DANGER: Electrical shock hazard. Disconnect power before cleaning.
Exterior Parts
25cm
Use a mild, non-abrasive soap and clean water solution to clean the metal cab-
(10")
inet, handles and wheels. Wipe dry.
Air Filter
Remove filter. Wash in a mild soap and water. Rinse with clean water. Air dry
before reinstalling. Torn or ripped filters should be replaced with a new filter.
Fan Motor
Does not require lubrication.
Condenser and Evaporator Coils
1. Light cleaning: Remove the air filter and
spray evaporator coil with water.
2
A
B
A qualified refrigeration technician must service all refrigerant leaks.
Important - If power to the unit is disconnected or unit is turned off, allow 3 minutes
before restarting the dehumidifier. This allows the internal pressures to equalize.
Storage:
Single unit: It is best to cover the unit if extended storage periods are contem-
plated. Remove all water in collection system.
Stacking Two Units: This dehumidifier can be stacked two high.
An assembled unit weighs 39 kgs (86 lbs). Position on a level surface.
2. Heavy cleaning: Open upper door. Remove
plastic cleanout by pushing the two locking
tabs and lifting. Spray water at coils. Replace
the cleanout.
WARNING: Personal injury hazard. Use two individuals to lift.
Maximum stacking height: 2 units