2.5
Type-identical identification marking
The facepiece is marked as follows:
EPDM or SI
Facepiece body
EN 136 CL. 3, CE0158
Equipment connector
P
PC (uncoated) or PC/CC (anti-fogging
Visor
coating inside/anti-scratch coating
outside) or L
Visor frame
K/rt
3
Use
3.1
Before use
Strictly follow OSHA 1910.134 and other valid national regulations
for the use of respiratory equipment.
Before using the facepiece for the first time, perform a leak test
(see chap. 4.3.4 on page 109).
Panorama Nova P
3.2
1. Loosen the facepiece from the standby position.
2. Pull the head harness apart then put
3. Pull the head harness over your head
4. Adjust the facepiece.
5. Pull the straps until evenly tightened;
6. Don the helmet and make sure that it
7. Press the button and insert the lung
(Use Instructions for NIOSH-approved full facepieces)
Donning the facepiece
WARNING
!
Beards and sideburns in the sealing range of the facepiece
will cause leaks! Therefore the facepiece should not be used
by anyone with facial hair of this sort. Spectacle frames in the
sealing range also cause leaks. Use facepiece spectacles.
NOTICE
i
i
At very low temperatures, the user can reduce facepiece
fogging by either inhaling or holding his breath when donning
the facepiece.
your chin into chin cup of the facepiece
body.
and draw backwards.
first the neck straps (1), then the temple
straps (2), finally the front strap (3).
fits correctly.
demand valve into the equipment connector.
3
2
1
105