Install the electrical T-distributor
Warning!
• Operate the product only with safety extra low voltage (SELV). The components
must not be earthed.
• Place the power supply (not part of the delivery , see accessories,
outside the wet area in a separate room.
• Protect the power supply with a residual current circuit breaker (RCD).
Failure to observe this instruction can result in death or material damage due to
electric shock or fire, for example.
☞
Important!
The components of the electrical T-distributor may only be installed after the power
has been switched off.
☞
Recommended system lines see
When using cables other than the system line, pay attention to the different colour
code. The outer diameter must not exceed 7.5 mm.
11.19 Remove the sleeving (q) of the system lines (approx. 40 mm).
11.20 Push the union nut (s) onto the system line (r) up to the limit stop.
☞
The various wire guides are marked with numbers 1 to 4.
A: Union nut
B: FAR-Best.-Nr. 2000104272
FAR-Best.-Nr. 2000104274
FAR-Best.-Nr. 2000100801
FAR-Best.-Nr. 2000100852
11.21 Push the wires (t) into the wire guides (u) according to their colours.
11.22 Cut off the projecting wire ends flush, i.e. without protrusions.
11.23 Push the union nut (s) onto the electrical T-distributor (v) and tighten it to the
required torque (1.2 Nm).
Caution!
Note the polarity.
The same wire colour must be in the same wire guide for both union nuts.
☞
When tightening the union nut, the electrical contact and tension relief are created
automatically.
Special seals act as protection from dust and water.
11.24 Connect the electrical T-distributor to the electronic module (see
11.25 Open the water volume regulators (see
Chapter
15., accessories.
1
brown
2
white
3
blue
4
black
Work step
11.5).
- 7 -