The device may only be used for the disinfec-
tion of baby bottles and their accessories as
well as other boil-proof items (please follow
the applicable instructions of the relevant
product). Incorrect usage of the device may
expose the user to considerable risk.
The heating jacket becomes very hot during
operation and hot steam flows through the
holes in the cover. To prevent burning and
scalding, please do not touch these parts
during operation.
Only move and clean the device once it has
cooled down.
Pull the mains connector out of the socket
when the device is not being used and before
removing device parts.
Do not remove the cover if the water is still
boiling.
Always stay near the device when it is in
operation.
Repairs may only be carried out by authorised
specialists.
Only use the components supplied for the
device.
Keep away from children and animals.
The device may not be used if visibly dama-
ged.
To prevent hazards in the event the power
cable for this device is damaged, it must be
replaced by the manufacturer, its customer
service department or similarly qualified
persons.
Persons (including children) not capable of
using the device safely because of their physi-
cal, sensory or mental aptitude, or because of
their lack of experience or knowledge, should
not use this device unsupervised or without
being under instruction from a person in
charge.
Do not touch hot parts with bare hands as this
presents a risk of burning.
The device is only suitable for use in dry
rooms.
The device must be on a dry, level surface
when being used.
8
Never completely fill the device with water
and never immerse in water or other liquids.
Only switch the device on when it is filled with
water.
Do not move the device whilst it is being used.
Do not open the device immediately after the
disinfection process, allow it to cool down
instead. Bottles and other disinfected items
are also very hot. Allow them to cool down for
approx. 5 minutes before removing them.
3. BEFORE DISINFECTION
Important! All items to be disinfected
must be washed cleanly and be free of
any food leftovers.
4. STARTING
see figures 1-11
12. Now all of the items in the device can be remo-
ved (bottles using the bottle grip included) and
the remaining water poured out.
13. Before using the device again for disinfection,
the device must be allowed to cool down for
at least 8-10 minutes so that the thermostat
resets to its original position.
14. Disconnect the device from the power supply
after sterilising your items.
Note! After the disinfection process
has started, it can only be stopped by
disconnecting the power supply.
5. CLEANING AND C ARE
CLEANING
Ensure that the device is disconnected from the
mains and cooled down before cleaning. Never
clean the device when it is hot. Do not use
abrasive cleaning agents or pot scrubbers, since
this would affect the surface of the device.
After each use, clean the device and the cover