Tecnomac AQUAMAC 100 Manual De Instrucciones página 17

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 39
GB
START-UP
When the water cooler is connected to the
water and electricity supplies:
1) Set the main power switch (yellow rocker
switch on left) to "ON"
comp
def
(3) Automatic filling ON/OFF switch
(1) Main power
switch
2) Using the remote digital thermostat, preset
the required water temperature as follows:
OPERATION: during normal operation the
value measured by the ambient sensor is
displayed. During alarm conditions the tem-
18
5. OPERATING INSTRUCTIONS
(2) Thermostat
PRG
mute
aux
def
SEL
(4) Pressure
vessel pump
ON/OFF switch
YOU MUST REQUEST THE ASSISTANCE OF A LICENSED TECHNICAL
TO SOLVE THE FOLLOWING FAULTS:
1. CONTROL PANEL NOT WORKING
2. COMPRESSOR DOES NOT START
3. REMOTE THERMOSTAT NOT FUNCTIONING
4. PUMP BREAKDOWN
5. ALL OTHER CASES OF OPERATIONAL FAULTS
perature display alternates with the alarm
code.
SET-POINT:
– Press SEL momentarily to display the set-
point value;
– After a few seconds the displayed value
will start to flash;
– Increase or decrease the value as
required using the
– Press SEL again to confirm the new value.
3) The central green coloured switch serves to
enable or disable tank filling (when disabled,
prevents warmer mains water from being
mixed with accumulated chilled water). This
is important when water must be supplied at
a constant temperature.
4) The switch on the right (pressure vessel ver-
sions only) serves to enable or disable pres-
sure vessel pump operation.
Make sure you do not draw off all the chilled
water or the pressure vessel pump will run
empty with the consequent risk of breakdown.
NOTE: When the pressure vessel pump is run-
ning, mains water inlet is automatically exclud-
ed.
W W
A A
R R
N N
I I
N N
G G
W W
A A
R R
N N
I I
N N
G G
def
aux
! !
! !
keys

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Aquamac 150Aquamac 200

Tabla de contenido