What If There Are Problems; Disposal; Replacement Parts And Wearing Parts; Technical Data - Beurer LR 330 Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 33

8. What if there are problems?

Problem
The air purifier will not switch on.
Clicking sounds are heard during
operation.
Moisture develops around the
device.
The disc set does not turn.

9. Disposal

For environmental reasons, do not dispose of the device in the household waste at the end of its useful life.
Dispose of the unit at a suitable local collection or recycling point. Dispose of the device in accord-
ance with EC Directive – WEEE (Waste Electrical and Electronic Equipment).
If you have any questions, please contact the local authorities responsible for waste disposal.

10. Replacement parts and wearing parts

Replacement parts and wearing parts are available from the corresponding service address (according to the
service address list). Please state the corresponding order number.
Designation
Pre-filter, combi filter (activated carbon /
HEPA filter class E 10)
Water tank
Disc set

11. Technical data

Model
Mains voltage / Output
Dimensions (L x W x H)
Empty weight
Suitable for rooms
Tank capacity
Tray capacity
Evaporation output
Permissible operating conditions
Protection class
Cause
There is no water in the tray.
The mains part plug is not plugged
in.
The disc set is not correctly insert-
ed into the device.
Limescale deposits have accumu-
lated in the tray.
Water is escaping from the hous-
ing.
The disc set is not correctly seat-
ed in the tray.
Item number and/or order number
660.11
163.653
163.654
LR 330
See type plate on the device
370 x 260 x 362 mm
6.7 kg
up to approx. 35 m
4.6 l
1.3 l
up to 220 ml/h
+5°C to +40°C, ≤ 90% relative humidity (non-condensing)
Protection class II
22
Solution
Fill up the water tank as described
in chapter 6.5.
Plug the mains part plug into a suit-
able socket.
Correctly insert the disc set into the
device.
Remove the limescale deposits from
the tray.
Empty the water from the tray and
allow it to dry for 24 hours.
Carefully insert the disc set into the
tray.
2

Publicidad

Tabla de contenido
loading

Tabla de contenido