Controls
L
Button Function
L
Turns the lights ON/OFF at maximum strength.
T1
Turns the motor on/off at speed one.
Delay Function:
Press and hold the button for approx. 3 seconds to Activate/Deactivate the
Delay function (automatic switching off of the Motor, the Fans and the Lighting
with a 30' delay).
Cannot be enabled when Intensive or 24H are on.
T2
Turns the Motor on at speed two.
Press and hold the button for approximately 5 seconds, with all the loads
turned off (Motor and Lights), to turn the Activated Charcoal Filter alarm on.
To turn the alarm off, press the button again and hold for at least 5 seconds.
T3
Turns the Motor on at speed three.
Press and hold the button for approximately 3 seconds, with all the loads
turned off (Motor and Lights), to reset the Filter saturation alarm. The
LED S1
T4
Turns the Motor on at INTENSIVE.
This speed is timed to run for 6 minutes. At the end of this time, the
system returns automatically to the speed that was set before. If it is
activated with the motor turned off, the hood will switch to OFF at the
end of the time.
Press and hold for 5 seconds to enable the remote control, indicated by
Press and hold for 5 seconds to disable the remote control, indicated by
S1
Signals the Metal Grease Filter saturation alarm, indicating that it is
been in operation for 100 working hours.
changed after the Hood has been working for 200 hours.
T1
T2
T3
T4
S1
Led
-
-
Flashing
-
Flashing
-
Flashing
-
Flashing
Fixed
Flashing
9