USAGE
RGB colour spotlight only
The system offers 16 programs including 11 static colours and 5 automatic modes.
The control is made manually by the remote controller provided and also short cuts of the current. Each fast cut of the current (less than 2 seconds)
makes change the programs. After leaving the lamps OFF for over 10 seconds, switch ON restarts from the last program used.
The use of the remote controller requires a positioning facia to the lamp at a maximum distance of 10 meters, unfolded antenna. Metallic part closed
to the lamp can cut the radio reception and the distance of use under 1 to 2 meters.
At first use, the remote controller needs to be paired with the receiver installed in the projector.
Pairing process:
• Install the battery in the remote controller and switch on the projector
• Switch it OFF for a minimum of 10 seconds and turn ON the current again
• Make fast OFF/ON/OFF/ON from the power supply of the lamp(s)
• Press the buttons O & S together during 1 second
• Each lamp connected flash several times to valid the pairing and keep a static colour Press several times the button C or P until obtaining the colour
or the desired program.
Maintenance
Parts must only be replaced with genuine spare parts.
You are advised to change all the sealing parts when a bulb and/or the cable are changed.
If a fault occurs, the complete LED bulb must be replaced. Do not try to open or repair it.
If the power cord or the sheath is damaged, it must be replaced by the manufacturer, an approved service centre or a qualified technician to avoid any
risk of accident.
O : On / Off
S : Synchronizing function
C : Colors 1 to 11
P : Programs 1 to 5
MN23 type 12Volts alkaline battery provided
USE ONLY hAYWARD GENUINE REPLACEMENT PARTS