6.2
Indicator panel
!
CAUTION!
Do not install indicator panel in an atmosphere with potentially flam-
mable or explosive vapors.
When selecting the installation location observe the following information:
• Select panel location away from direct contact with water and oil.
• Confirm clearance of 50 mm for wire connections behind wall, hull liner or bulk-
head.
• Make sure the electrical power is shut off.
I
NOTE
For electrical connections refer to wiring diagram (fig. 3, page 3).
Install the indicator panel as follows (fig. 4, page 4):
➤ Using indicator panel template, cut out panel access hole (1) and drill fastener
holes (2).
I
NOTE
Make sure wires extend out through access hole (1).
➤ Route 1 mm
2
stranded copper wire from power source, through 0.5 A fuse (not
provided), to panel location.
➤ Route 1 mm
2
stranded copper wire from holding tank probe assembly to panel
location.
➤ Install mounting frame (3) with four #6 (3.5 mm) fasteners (4).
➤ Make proper 12 Vg or 24 Vg wiring connections to indicator panel (5).
➤ Push indicator panel (5) onto mounting frame (3) until it locks into place.
EN
Installation
9