Precipitation safety
snow and frost
n
The maximum load for which the non-retractable parts of the framework have been designed is higher than the minimum
requirements of the EN 13561:2015 standard equal to 800 Pa. If you require the specific data please contact your authorised
retailer. In case of snow or other top loads verify and remove any element from the moving parts (blades) before activating the
opening, and keep the blades in an upright position (90°). Operation in freezing conditions can damage the product. In the
presence of ice/snow it is necessary to thoroughly clean the blades before using them.
rain
n
In the case of rain the blades must be completely closed and the water drainage system, with 2 perfectly maintained open
drainages and a perfectly flat gutter, is able to discharge about 3150 litres/hour with constant flow and guarantees with any
dimension a value that is considerably higher than class 2 (according to EN 13561:2015), equal to 56 l/h/m².
For non-standard products and/or other special cases, the only valid values in terms of wind resistance, resistance to water
pockets and maximum loads are those indicated in the offer and/or order confirmation sent by Corradi to the Authorised
Retailer.
It is possible to install a rain gauge for automatic blade adjustment if the indicated amount of rain is exceeded. Periodically
test its operation.
Important: If there is no device present for the automatic closure of the blades, always keep them closed if the framework is
not supervised.
Risk of shearing/crushing
A height of passage lower than 2.5 m can generate the risk of shearing/crushing between the mobile part (adjustable blades) and the fixed
part of the framework.
The risk of shearing/crushing is also present between the blades during the phase of opening and closing.
The presence of the person commanding the movement is always mandatory until the end of the movement to make sure that there are
no obstacles or people in the vicinity of the area of potential danger.

Risk of electric shock

The inspection, maintenance or repair of electrical components should be performed by qualified personnel only, making sure the product
is fully disconnected from the power supply. There is in fact a danger of fatal electric shock.
Frequently examine the installation, check for any signs of wear or damage to the cables.
Do not use if a repair is necessary.
If not used for an long period of time, protect the visible mechanical parts.