NOTE:
If you want to modify the file name of the configuration after saving it on the PC, please take note that the
name must be no longer than 16 letters ( ".cpr" extension not included) and that special symbols are not
accepted.
After loading the configuration onto the FIL, we recommend that you perform the self-alignment operation
as specified in paragraph 5.4.
Printing
The Print function allows for the configuration to be printed either in graphics mode or in text mode. To print,
click File and then Print.
The FIL unit can be upgraded by a PC by means of the RJ45 serial port. To find the last firmware, refer to the
section "Software updating" within the website www.fracarro.com.
16 letters on 2 row display, built-in keypad for programming
Green LED that shows that the unit is working properly
3 LEDs on the UHF inputs that indicate that remote power supply is enabled (2 LEDs on FIL 06).
USB 2.0 port to load/save configuration file by means of a USB pen drive
RJ45 port for upgrade firmware
Thermal compensation of the gain for UHF inputs
Self-leveling of signals levels
Cluster selectivity (dB)
Separation between inputs (dB)
Connectors
Return loss IN/OUT (dB)
Supply voltage (Vac)
Consumption (A)
Protection degree
Operating temperature
Dimensions (mm)
Technical data is nominal values and refer to an operating temperature of 25° C.
7. FIRMWARE UPGRADE
8. TECHNICAL SPECIFICATIONS
General features of the FIL product
20dB @ 10MHz
220-240 @ 50-60Hz
1.6 (FIL 10) – 1.3 (FIL 06)
FIL 10
FIL 06
40
≥ 30
75 Ω (Tipo F)
≥ 10
IP20
-5 ÷ 55 °C
230X230X50
160X230X50