Ac Power Connection; Rear Panel - Fujitsu CG-311 Serie Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

POWER CONNECTION
This camera uses 24VAC or 12VDC power sup-
ply for the main supply.
CAUTION:
Take care not to short-circuit the power line
wire, when connecting the power-supply
cord to the camera.
A. AC POWER CONNECTION
PAL:
A main supply of 24VAC (21.6 to 26.4 VAC)
50Hz is required.
NTSC: A main supply of 24VAC (21.6 to 26.4 VAC)
60Hz is required.
This main supply must also have a minimum
rating of 270mA.
Remove the sheath at the end of power cord in
the length of 10mm.
Twist and straighten the wires, then insert the
wires to three holes of the terminal.
If the insertion can not be made smoothly, try
it again while pushing respective button above
the hole.
En-10
CAUTION:
Confirm that the cord is connected to the
terminal securely by pulling the cord.
Confirm that there is no whisker of wires
outside the holes of terminal.
Connect to 24VAC class 2 power supply only.
Make sure to connect the grounding lead to the
GND terminal when the power is supplied from a
24VAC power source.
CAUTION:
When two or more cameras are used by
one transformer, use a transformer having
the rated current more than the current
consumed with the number of cameras ×24VAC 270
mA.
TRANSFORMER
INPUT
OUTPUT

REAR PANEL

Button
AC 24 V
Fig.5

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Cg-311nCg-311p

Tabla de contenido