The ABSOLUTA MTOUCH keypad can be used on security
systems with up to 104 zones. This keypad is compatible
with ABSOLUTA version 3 control panels and later.
Specifications
• Temperature range: -10 °C to +55 °C.
• Humidity (MAX): 93% R.H. non-condensing.
• Plastic enclosure protection degree: IP30, IK04 (touchscreen
excluded).
• Voltage rating: 12 V
nominal.
DC
• Connects to control panel via 4-wire BPI bus.
• Bus length: 150 m (max) @ 330 mA with 0.5 mm
• Up to 16 keypads per system.
• Current draw: 100 mA standby (screen off); 200 mA acti-
vated or alarm (Screen Brightness: Normal); 300 mA
activated or alarm (Screen Brightness: Extra high).
• Wall mount tamper.
• User Login (Green LED), Armed (Red LED), Trouble (Yellow
LED), Power (Green LED).
• Dimensions (WxLxD): 195 x 127.9 x 20.35 mm.
• SD card slot: holds any standard Secure Digital (SD) card*
(32 x 24 x 2.1 mm).
*If necessary, the SD card can be formatted to file system
FAT16 or 32 using a PC. The maximum size SD card sup-
ported is 32 GB.
• Wiring: standard four-wire connection.
• Viewing angle: horizontal viewing angle: 70° (typ.).
• Vertical viewing angle: 50° (top), 70° (bottom) (typ.).
2
• Brightness: 280 cd/m
.
Unpacking
The ABSOLUTA M-TOUCH keypad package includes the fol-
lowing parts:
• One ABSOLUTA M-TOUCH
• Five mounting screws
• Five anchors for wall-mounting screws
• Installation Instructions
Mounting
Mount the keypad where it is accessible to designated
points of entry and exit. Once a dry and secure location has
been selected, perform the following steps to mount the
keypad.
1. Remove the SD card before opening the touchscreen (see
Figure 1).
WARNING: Disassembling the touchscreen without removing
the SD card will damage the unit.
2. Remove screw at the bottom of the keypad.
3. Insert screwdriver into slots and pry up to remove cover.
Figure 1 - Removing the backplate
4. Secure keypad backplate to wall using mounting holes.
(See Figure 2.) Use all 4 screws provided unless
2
cable.
mounting on a flush box. Use the plastic anchors
supplied if the unit is to be mounted on drywall. If using
the keypad tamper, secure the tamper plate to the wall
with a screw.
5. Run wire through wiring slot. Connect BPI bus wiring to
keypad (see Wiring section).
Figure 1 - Removing the backplate.
6. Place keypad into backplate, ensuring the wire is pushed
back into the wall as much as possible. Route the wire
inside the keypad ensuring high components are
avoided. Snap the front assembly closed, ensuring that
there is no pressure to the keypad from the wire below.
NOTE: If any tension is found between the front keypad
assembly and wiring, open the keypad, re-route the wire and
close again. Repeat these steps until the keypad is closed
properly.
Wiring
1. Before wiring the unit, ensure that all power (AC
transformer, telecommunication network, and battery) is
disconnected from the control panel.
2. Connect the four BPI bus wires from the control panel
(+, C, R, –) to the keypad terminals as shown in
Figure 3.
Applying Power
Once all wiring is complete, and the equipment is secured
to the building structure with at least two screws, apply
power to the control panel, as described in the instructions.
WARNING: Route all the wiring according to the local codes
and regulations.
press
gently
SD
to
push
card
eject
in
Figure 2 - Mounting the backplate.
mounting hole
mounting hole
mounting hole
wiring slot
wiring slot
hole for
hole for
tamper
tamper
screw
screw
mounting hole
mounting
mounting
hole
hole