GB
Safety notes
Prevent danger resulting from damaged power
supply cables. In the case of damage, the power
supply cable must be replaced by the manufacturer
or his customer service department or an equally
qualified person.
• Installation is only possible in frost-free rooms.
• The optional power supply unit is only suitable for indoor
use.
• The plug-in connectors must not be directly or indirectly
sprayed with water when cleaning.
• The voltage supply must be separately switchable.
• The maximum permissible distance between the digital
controller and the functional unit is 5 m.
Application
Can be used in conjunction with:
• Pressurised storage heaters
Must not be used in conjunction with:
• Thermally controlled instantaneous water heaters
• Hydraulically controlled instantaneous water heaters
• Unpressurised storage heaters (displacement water
heaters)
Technical data
• Flow pressure:
- min.
- recommended
• Operating pressure:
• Test pressure:
A pressure-reducing valve must be fitted if static pressure
exceeds 0.5 MPa.
Avoid major pressure differences between hot and cold water
supply.
• Flow rate at 0.3 MPa flow pressure:
• Hot water supply temperature:
Recommended (energy saving):
• Voltage supply:
• Power consumption:
• Radio frequency:
• Transmitter power:
• Emergency power supply: 6 V lithium battery (type CR-P2)
• Digital controller battery:
3x 3 V lithium batteries (type CR 2450)
• Automatic safety shut-off (factory setting):
• Safety stop:
• Type of protection:
• Water connection:
Electrical test data
• Software class:
• Contamination class:
• Rated surge voltage:
• Temperature for ball impact test:
The test for electromagnetic compatibility (interference
emission test) was performed at the rated voltage and
rated current.
5
For latest prices and delivery to your door visit MyTub Ltd - www.mytub.co.uk - info@mytub.co.uk
Approval and conformity
The conformity declarations can be obtained from the following
address:
GROHE Deutschland Vertriebs GmbH
Zur Porta 9
D-32457 Porta Westfalica
Electrical installation
local regulations.
Installation
Install spout, see fold-out page II, Figs. [1] and [2].
Install pop-up waste (65 807), see fold-out page I.
Seal plug-hole rim.
Insert batteries into digital controller, see technical product
information for the digital controller. Insert batteries with
correct polarity.
The digital controller is registered with the functional unit in the
0.1 MPa
factory.
0.2 - 0.5 MPa
Fasten digital controller, see technical product information
max. 1.0 MPa
for the digital controller.
1.6 MPa
The adhesive film must be allowed to cure for 24 hours before
the digital controller is removed for the first time.
Install functional unit, see Fig. [3].
Flush pipes thoroughly before and after installation
(observe EN 806).
approx. 9 l/min
Connect functional unit, see Figs. [4] and [5].
min. 50 °C - max. 80 °C
60 °C
Open hot and cold water supply and check that
230 V AC, 50/60 Hz
connections are watertight. Water flows until the voltage
9 VA
supply is established.
2.4332 GHz
Connect battery housing to functional unit, see Fig. [4].
< 1 mW
Establish voltage supply via plug-in power supply, see
Fig. [4] and fold-out page I.
The connecting wire can be extended using the extension
cable special accessory (Prod. no. 47 727). A maximum of two
extension cables can be joined together (max. 6 m).
60 s
The reception can be improved and thermal disinfection
42 °C
carried out using the transceiver special accessory
- Fitting
IP 66
(Prod. no. 36 356).
- Battery box
IP 59K
Approx. 10 seconds after the voltage supply is established
- Digital controller
IP X5
there are two brief water pulses and the buttons of the digital
cold on right/hot on left
controller are now inoperative for 60 seconds.
The fitting must be adapted to the local conditions, see section
Selection menu of the digital controller, F2 - Calibration.
B
Settings during power failure/when changing batteries
2
No settings saved by the user will be lost when changing the
2,500 V
batteries or in the event of an interruption of the power supply
100 °C
to the functional unit.
This product conforms to the requirements of the
relevant EU guidelines.
Electrical installation work must only be
performed
by a qualified electrician. This work must be
carried out in accordance with the regulations
according to IEC 364-7-701-1984 (corresponding
to VDE 0100 Part 701) as well as all national and