Greenlee NC-500 NETcat Manual De Instrucciones página 12

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Test Details (cont'd)
Wiremap
This test checks the cable for correct wiring when a remote/Office ID is connected to the end
of the cable under test. The cable configuration is tested for shield continuity (if fitted), opens,
shorts, reversed pairs, crossed pairs, and split pairs. Below are examples of detectable faults
along with a good wiremap.
Good wiremap.
Wiremap with a miswire
between pairs 4-5 and 7-8.
12
Wiremap with an open at
10 ft on pair 1-2 and shield
disconnected.
Wiremap with a split pair
on 1-2 and 7-8 and shield
disconnected.
Wiremap with a short at
11 ft on pair 1-2 and shield
disconnected.
Wiremap with a reversed pair
on 1-2 and shield disconnected.

Publicidad

Tabla de contenido
loading

Tabla de contenido