MOTOR "SOUNDS" BUT FAILS TO START
Insufficient power supply: Check that the volt-
age of the mains power supply line is the same
as that on the plate.
Voltage loss due to use of extension cable:
Check characteristics of extension cable.
Appliance not used for a long period of time:
Contact your nearest Authorized Service Cent-
er.
Problems with TSS device: Contact your near-
est Authorized Service Center.
MOTOR FAILS TO START
No electrical power: Check that the plug is
firmly in the socket and that the mains voltage
supply is present.
Problems with TSS device: Contact your near-
est Authorized Service Center.
Appliance not used for a long period of time:
Using the tool unjam the motor from the hole
at the rear of the appliance (in models with
this feature).
WATER LEAKAGE
Seals worn: Have the seals replaced at your
nearest Authorized Service Center
APPLIANCE NOISY
Water too hot: Reduce temperature (see tech-
nical data).
OIL LEAKAGE
Seals worn: Contact your nearest Authorized
Service Center.
MOTOR STARTS EVEN WITH GUN TRIGGER
IS RELEASED
Nozzle clogged: Clean nozzle.
High pressure system or pump hydraulic circuit
not watertight: Contact your nearest Author-
ized Service Center.
E N G L I S H •

TECHNICAL DATA

VOLTAGE-FREQUENCY
MAX. PRESSURE
MAXIMUM PRESSURE OF
WATER INLET
FLOW
POWER
WEIGHT
U se r 's m a nu a l
120 V ~ 60 Hz
10 MPa (1 450 PSI)
147 KPa
6 L/min
1 400 W
6,5 kg (14,3 lb)