7. PROGRAMMING THROUGH GTSYSTEM

The GTSYSTEM is an autonomous multi-functional terminal that can be used on various Prastel products both
for testing and function modification. In the case of UNIK2E control unit, it allows:
modification or visualisation of operating parameters,
visualisation of the counter of completed manoeuvres,
visualisation of the control unit status and diagnostic messages.

8. ACCESSORIES ABSORPTION CHECK INFORMATION

(Transformer dimensioning)
The current available for the accessories is given by the power available for the accessories divided by the
voltage of the accessories (13.7V).
Pacc
Iacc =
13.7
The power available for the accessories is given by the transformer power, less the motor power, less the power
absorbed by the control unit (4W).
Pacc = Ptras – Pmot – 4
Below are two examples of calculation of the current available for the accessories.
Control
Transformer
Unit
Power
UNIK2E
80VA
UNIK2E
100VA
The following table shows the average absorption of the most common Prastel/VDS accessories
Product
Flashing Light FEBOLIX
Photocell FOTO30SDE (couple TX+RX)
Photocell FOTO35SDE (couple TX+RX)
Induction detector MLX24AZ
Receiver MR1E
Microwave detector DM30
Microwave detector DM60
Amplifier for infra-red barrier FOTOTEST2D
Pneumatic edge receiver TCO4RX
Standalone keypad EASYBKA
Standalone proximity reader EASYMINI
Example: connecting 2 pairs of FOTO30SDE photocells, a FEBOLIX flashing light and a MLX24AZ detector the
overall average absorption is 290mA. Should it be necessary to connect accessories with an overall average
absorption that is more than that available, the transformer must be replaced with a more powerful one. For
12VDC motors use transformers with a secondary of 12VAC (for 24VDC motors use a transformer with a
secondary of 20VAC).
ENGLISH
Iacc = current available for accessories
Pacc = power available for accessories
Ptras = transformer power
Pmot = motor power 1 + motor power 2
Power
Power absorbed
absorbed by
by the motor
the control
unit
70W
4W
85W
4W
13
Power available
Voltage of the
for the
accessories
accessories
6W
13.7V
11W
13.7V
Absorption
150 mA
50 mA
50 mA
40 mA
20 mA
80 mA
100 mA
30 mA
30 mA
100 mA
30 mA
ISUNIK2Ev2_EU_10_12.doc
Current
available for the
accessories
430mA