Overhead Rigging - BEGLEC JB SYSTEMS LED SPOT Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 17
ENGLISH
Follow the these steps (in this example the start address is set to 403):
 Make sure the DMX cables of all units are connected.
 Connect all units to the mains so they are switched on.
 Edit scene1: CH1= 0, CH2= 255, CH3= 1, CH4= 146
 Edit scene2: CH1= 255, CH2= 0, CH3= 1, CH4= 146
 Program these 2 scenes in a chase and run it to automatically set the DMX addresses.
You will notice that all units flash 1x to indicate that the addresses are set.
 Press the blackout button on your controller 2times to set all units in blackout and back on.
 Done: in this case the first unit has start address 403, the 2
address 411, ...
Remark: you can mix the units with other DMX-effects that don't have the remote DMX-addressing
option. In that case you still have to set the DMX-addresses of these DMX-effects manually!

OVERHEAD RIGGING

 Important: The installation must be carried out by qualified service personal only. Improper
installation can result in serious injuries and/or damage to property. Overhead rigging requires
extensive experience! Working load limits should be respected, certified installation materials
should be used, the installed device should be inspected regularly for safety.
 Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging
and servicing.
 The device should be installed out of reach of people and outside areas where persons may walk by or be
seated.
 Before rigging make sure that the installation area can hold a minimum point load of 10times the device's
weight.
 Always use a certified safety cable that can hold 12times the weight of the device when installing the unit.
This secondary safety attachment should be installed in a way that no part of the installation can drop
more than 20cm if the main attachment fails.
 The device should be well fixed; a free-swinging mounting is dangerous and may not be considered!
 The operator has to make sure that the safety-relating and machine-technical installations are approved by
an expert before using them for the first time. The installations should be inspected every year by a skilled
person to be sure that safety is still optimal.
 3 different fixing methods are possible:
 Fixed to ALU truss: use an optional truss clamp.
 Fixed to wall or ceiling: use 2 adapted screws to fix the base plate (5) to a wall or ceiling.
 On a horizontal surface: just fix the unit on the included base plate (5) and put it on a stable, horizontal
surface.
Placed on a horizontal
Fixed to wall or
surface
JB SYSTEMS®
OPERATION MANUAL
nd
has address 407, the 3
Fixed to ALU-truss
ceiling
5/44
LED SPOT – LED WASH
ENGLISH
OPERATING INSTRUCTIONS
A. Standalone 1unit:
 Just connect the unit to the mains and put on some music. The unit starts working automatically to the
rhythm of the music.
Remark: You can connect a CA-8 remote controller to the unit if you want to have more control.
B. Two or more units in master/slave setup:
 Connect 2 to maximum 16 units together. Refer to the chapter "electrical installation" to learn how to
do this (don't forget to address all units properly!)
rd
has
 Connect all units to the mains and put on some music. The units will start working automatically to the
rhythm of the music and show the internal chase programs.
Remark: You can connect a CA-8 remote controller to the master unit if you want to have more control
over the master/slave operation.
C. Connect the optional CA-8 controller for more control:
The CA-8 controller can only be used in standalone or master/slave mode. Connect the controller to the
CA-8 input of the first unit (master). Now you can control all the connected units:
BUTTON
STANDBY
FUNCTION
MODE
D. Controlled by universal DMX-controller:
 Connect all units together. Refer to the chapter "Electrical installation for two or more units in DMX-
mode" to learn how to do this (don't forget to address all units properly!)
 Connect all units to the mains and turn on the DMX controller.
Since each unit has its own DMX-address, you can control them individually. Remember that each unit
uses 4 DMX-channels as shown in the DMX chart below:
JB SYSTEMS®
ACTIONS
To blackout all the fixtures
Strobe
9 Color select
Color Chase
White  Red 
1.Synchronous strobe
1. The same color
Blue  Purple 
in white color
2. Different color
Orange  Green 
2.The same color
3. One light chase
Yellow  Magenta
chase
4. Two lights chase
 Cyan
3.Differentcolor
5. Four lights chase
strobe
Sound 1
Manual
Sound 2
(LED OFF)
(LED ON)
(LED slow blinking)
6/44
OPERATION MANUAL
Color Fade
1. Fast speed
2. Middle speed
3. Slow speed
Auto
(LED fast blinking)
LED SPOT – LED WASH

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Jb systems led wash

Tabla de contenido