The Pico Technology Mixmaster is a 12-channel ignition signal mixer for the
Automotive Oscilloscope Kit. It allows you to view an ignition parade display of up
to twelve cylinders on any oscilloscope. Each product pack contains the following
items:
Mixmaster
TA027 secondary pickup leads, pack of 4*
Cable identifier kit
* You can purchase extra sets of secondary pickup leads for use with up to 12
channels.
Please read the important information in this introductory section before proceeding
to the Product Information.
1.2

Safety symbols

Warning Triangle. This symbol indicates that a safety hazard exists on
the indicated connections if correct precautions are not taken. Ensure
that you read all safety documentation associated with the product before
using it.
Equipotential. This symbol indicates that the outer conductors of all the
BNC sockets on the Mixmaster are electrically connected together. Take
care not to connect these, either directly or through cables, to any
external conductor that is not at ground or earth potential.
1.3

Safety warnings

We strongly recommend that you read the general safety information below before
using your Mixmaster for the first time. Safety protection built in to the equipment
may cease to function if the equipment is used incorrectly. This could cause
damage to your computer, or lead to injury to yourself and others.
Maximum input range
The Mixmaster is designed to measure voltages in the range -20 kV to +20 kV
when used with the secondary ignition pickup leads supplied. The unit's BNC inputs
are designed to operate with voltages in the range -2 V to +2 V and are protected
against continuous or transient overvoltages of up to ±4 V. Any voltages exceeding
this may cause permanent damage to the unit, your oscilloscope or your computer.
Measurement category
The Mixmaster is rated for use in measurement category I (EN61010 CAT I),
which covers measurements on circuits not connected to the mains. You must not
use the unit to make measurements on any circuit directly connected to the mains.