Change of fuse (only TEB-3 – 12 V)
Observe the ESD-regulations!
The fuse (F1) is located on the electronic control unit in
the device.
–
Disconnect the fan from the power source (disconnect
battery, or remove mains plugs).
–
Remove the power supply plug and control panel plug.
–
Unscrew the 2 screws (1) on the housing – remove housing.
–
Touch the PCB on the edge and remove from the device.
–
Only replace faulty fuses with ones of the same type
(see "Technical Data").
–
Insert the PCB into the housing.
–
After replacing the fuse, attach the housing to the fan using
the 2 screws (1).
–
Connect the plug of the control panel and the power cable
plug (check that the unit is wired correctly – otherwise the
control panel will not function and the fan will rotate in the
wrong direction.).
–
Connect the battery again; if necessary reconnect the
power supply.
10
1
F1
TN-3 – 230 V
External control panel
b
a
230 V ~
a = Knob for setting fan output (1 – 5)
b = Knob for the operating types
c = Off
d = On, manual setting of the fan output
Set required speed using the knob (a).
Disposal
The device must be disposed of in line with the administra-
tive regulations of the respective country in which it is used.
National regulations and laws (in Germany, for example, the
End-of-life Vehicle Regulation) must be observed.
Trumavent
c
d