Only one head on a complete installation should have a bypass val-
ue different from 0 to avoid boiler error (over heating) and guarantee
at least one heat zone circulation on the installation. It is equivalent
to let a heater partially opened for in the installation (It is usually
implemented on the bath room heater).To be used with caution.
In the set-up2 menu, go on the 3rd LED.
Move left and right to decrease/increase bypass value with 10% steps.
Possible values [ 0%;20% to 70% ].
0%
20%
50%
60%
Push OK to validate and go back to SETUP 2 selection menu.
2.11 Exit of the setup2 menu
Select the 6th LED and confirm.
3. States description
Rules:
-
Need to push OK button to wake-up the HEAD
-
After any action, the HEAD is wake-up for 5s and return to stanby
-
Keylock procedure : Push 3 times the OK button
-
Switch ON / OFF mode : Push the OK button for 3s
START-UP
7th LED orange FIX alone: it is the power up state
(just after inserting batteries)
ON MODE
7th LED green FIX and other 6 leds in any state

OFF MODE

7th LED RED FIX alone
Cod. 1910000000260 - nv00
30%
40%
70%
- 15 -
KEY-LOCKED
All leds red during 2s.
After shows the actual ON/OFF state
4. Setpoint description
The default setpoint is 19°C.
If Measured temperature >= Setpoint: leds are green (no heating de-
mand)
< 16°C
16°C
19°C
20°C
23°C
24°C
>26°C
If Measured temperature < Setpoint : leds are red (heating demand )
< 16°C
16°C
19°C
20°C
23°C
24°C
>26°C
English
17°C
18°C
21°C
22°C
25°C
26°C
Open window
17°C
18°C
21°C
22°C
25°C
26°C
Open window