Fault
The appliance turns on, but
the temperature is too high/
low
The appliance is leaking
water
The appliance is unusually
loud
The display lamp does not
illuminate
Door does not shut
Technical Specifications
Model
Voltage
HTR100 230V 50Hz
HTR120 230V 50Hz
HTR160 230V 50Hz
HAV91
230V 50Hz
HAV111 230V 50Hz
HAV131 230V 50Hz
HAVA120
230V 50Hz
SC96B
230V 50Hz
SC162B 230V 50Hz
SC204B 230V 50Hz
TCBD58 230V 50Hz
TCBD68 230V 50Hz
TCBD78 230V 50Hz
TCBD98 230V 50Hz
Probable Cause
Too much ice on the condenser
Condenser blocked with dust
Doors are not shut properly
Appliance is located near a heat
source, in the direct sunlight
or air flow to the condenser is
being interrupted
Ambient temperature is too
high
Unsuitable foodstuffs are being
stored in the appliance
Appliance is overloaded
Factory default parameters
adjusted
The appliance is not properly
levelled
Loose screw/nut
The appliance has not been
installed in a level or stable
position
Lamp needs replacing
Light not turned On
Dirt/obstacle in runners
Power
Current
160W
0.7A
3°C to 8°C
160W
0.7A
3°C to 8°C
200W
1.0A
3°C to 8°C
150W
1.0A
3°C to 8°C
150W
1.0A
3°C to 8°C
150W
1.0A
3°C to 8°C
150W
1.0A
3°C to 8°C
230W
1.6A
3°C to 8°C
230W
1.6A
3°C to 8°C
230W
1.6A
3°C to 8°C
164W
0.7A
3°C to 8°C
164W
0.7A
3°C to 8°C
184W
0.75A
3°C to 8°C
200W
1.0A
3°C to 8°C
Range
(litres)
88
118
150
110
148
187
170
101
160
202
70
82
94
117
Action Required
Defrost the appliance
Call or qualified technician
Check doors are shut and seals are
not damaged
Move the refrigerator to a more suit-
able location
Increase ventilation or move appliance
to a cooler position
Remove any excessive hot foodstuffs
or blockages to fan
Reduce the amount of food stored in
the appliance
Call or qualified technician
Adjust the screw feet to level the ap-
pliance (if applicable)
Check and tighten all nuts and screws
Check installation position and change
if necessary
Call or qualified technician
Ensure Light button has been pressed
properly
Clean runners
Refrigerant
H x W x D (mm)
R134a 100g
695 x 462 x 665
R134a 120g
695 x 580 x 665
R134a 130g
873 x 580 x 665
R134a 130g
910 x 510 x 550
R134a 130g
1110 x 510 x 550
R134a 130g
1310 x 510 x 550
R134a 130g
1200 x 475 x 520
R134a 125g
805 x 410 x 705
R134a 125g
805 x 410 x 925
R134a 125g
1005 x 410 x 925
R134a 130g
428 x 386 x 850
R134a 130g
428 x 386 x 925
R134a 130g
428 x 386 x 1000
R134a 130g
428 x 386 x 1150
UK
(kg)
57
64
71
53
75
81
55
70
85
95
30
32.5
36
81
5