Product Identification/ Produkt Identifikation/ Identification du produit/
Identificación de producto/ Identificazione prodotto
Note: the PLCM01 label is used as an example for PLCM01, PLCM05, PLCM09X, PLIO03
Hinweis: Das Etikett PLCM01 wird als Beispiel für PLCM01, PLCM05, PLCM09X, PLIO03 verwendet
Remarque: l'étiquette PLCM01 est utilisée comme exemple pour PLCM01, PLCM05, PLCM09X,
PLIO03
Nota: la etiqueta PLCM01 se utiliza como ejemplo para PLCM01, PLCM05, PLCM09X, PLIO03
Nota: l'etichetta del PLCM01 viene utilizzata come esempio per PLCM01, PLCM05, PLCM09X,
PLIO03
product model name
PLCM01
product part number
PLCM01U0P1
year/week of production
1816
serial number
AA0000225000000561AA
version id of the product
050100A00000000
manufacturer address and
Exor International S.p.A.
read instruction warning
Via Monte Fiorino 9
IT-37057 San Giovanni Lupatoto (VR)
TP_#12227_V01_200403
Below you can find relation between modules and max number of modules that can be used into
eX705 panel, based on their Interface Type:
Im Folgenden finden Sie die Beziehung zwischen Modulen und die maximale Anzahl an Modulen, die
in das eX705 Panel verwendet werden können, basierend auf deren Schnittstellentyp:
Vous trouverez ci-dessous la relation entre les modules et le nombre maximal de modules pouvant
être utilisés dans le panneau eX705, en fonction de leur type d'interface:
A continuación puede encontrar la relación entre los módulos y la cantidad máxima de módulos que
se pueden usar en el panel eX705, según su tipo de interfaz:
Di seguito è possibile trovare la relazione tra i moduli e il numero massimo di moduli che possono
essere utilizzati nel pannello eX705, in base al loro tipo di interfaccia:
Module
Application
Modul
Anwendung
Module
Application
Módulo
Aplicación
Modulo
Applicazione
PLCM01
CAN
PLCM01-NE
CAN
PLCM05
CODESYS
License
PLCM09X
3G modem
PLIO03
Multifunction I/O
PLCM01 / PLCM01-NE:
Operating temperature -20°C to 60°C
PLCM05:
Operating temperature -20°C to 60°C
PLCM09X:
Operating temperature -20°C to 60°C
PLIO03:
with part number PLIO03xxxxY where:
- Y≤2 is operating temperature range 0°C≤Tamb≤+50°C with
Operating Temperature Code T5 (vertical installation), 12-30VDC
- Y>2 is operating temperature range –20°C≤Tamb≤+60°C with
Operating Temperature Code T4 (vertical installation), 12-30VDC
Note the above different "Operating Temperature Code" for different part number of
PLIO03 module. / Beachten Sie die oben angegebenen unterschiedlichen "Operating
Temperature Code" für die verschiedenen Teilenummern des PLIO03-Moduls. / Notez
les différents "Operating Temperature Code" indiqués ci-dessus pour les différentes
références du module PLIO03. / Tenga en cuenta los diferentes "Operating Temperatu-
re Code" indicados anteriormente para los diferentes números de pieza del módulo
PLIO03. / Notare il diverso "Operating Temperature Code" sopra indicato per i diversi
part number del modulo PLIO03.
TP_#12227_V01_200403
Max Modules
Bus Extension connector
Max Module
Bus-Erweiterungsstecker
Max modules
Connecteur d'extension
Módulos Max
de bus
Moduli massimi
Conector de extensión de
bus
Connettore estensione
bus
1
Y
1
N
1
Y
1
Y
1
N
Installation Procedure/ Installationsverfahren/ Procédure d'installation/
Procedimiento de instalación/ Procedura d'installazione
VL-STYLE-KNX-TP / VL-STYLE-DIO-01
21
TP_#12227_V01_200403
PLCM and PLIO03 electrical ratings:
- PLCM01: For electrical rating refers to the host eX700 models.
- PLCM05: For electrical rating refers to the host eX700 models and PLIO03 ratings
- PLCM09X: 2xDigital Inputs voltage 12÷30 Vdc, 3mA; 2xDigital Outputs voltage 12÷30 Vdc, 0.5A
- PLIO03: 20xDigital Inputs voltage 12÷30 Vdc; 12xDigital Outputs voltage 12÷30 Vdc, 0.5A; 4xAnalog
inputs 0÷10 Vdc, 4-20mA; 4xAnalog outputs: 0÷10 Vdc, 4-20mA
Software available in this product is based on OpenSource. Visit oss.exorint.net for more details.
Die in diesem Produkt verfügbare Software basiert auf OpenSource. Besuchen Sie oss.exorint.net für
weitere Details.
Le logiciel disponible dans ce produit est basé sur OpenSource. Visitez oss.exorint.net pour plus de
détails.
El software disponible en este producto se basa en OpenSource. Visite oss.exorint.net para más
detalles.
Il software disponibile in questo prodotto si basa su OpenSource. Visita oss.exorint.net per maggiori
dettagli.
Reproduction of the contents of this copyrighted document, in whole or part, without written
permission of Exor International S.p.A., is prohibited.
Dieses Dokument ist urheberrechtlich geschützt. Das vervielfältigen in Auszügen oder im Ganzen
darf nicht ohne die schriftliche Zustimmung von Exor International S. p. A. vorgenommen werden.
Il est interdit de reproduire ou transmettre tout ou partie de ce manuel, a quelques fins que ce soit,
sans l'autorisation expresse de Exor International S.p.A.
Se prohibe la reproducción de cualquier parte de éste manual sin el permiso escrito de
Exor International S.p.A.
Nessuna parte di questo manuale puo' essere riprodotta senza il preventivo permesso scritto di Exor
International S.p.A.
12227_V01_200403, 03.04.2020
Copyright © 2020 DEUTA Controls GmbH
www.deuta-controls.net
23
22
24