After a interruption of the power
supply the time-switch will set
the basic setting of 60 minutes.
Remaining operating time
Press key
, the remaining op-
erating time shows on the dis-
play. After approx. 2 seconds the
remaining operating time can be
changed with the keys
or
The remaining operating time
can be deleted with key
.
12
Technical data
Current input
Digit display:
Light
12 V:
145 mA
24 V:
Cable lengths:
Trumatic E:
4 m
Trumatic C:
3 m
Cable extensions on request
.
Display of the remaining
running time
Key for immediate switch-on of
the heater
The Truma time-switch re-
ceives it 12 V power supply
from the heater-electronics
(also with the 24 V version
heaters).
Installation instructions
During works the current
3 mA
supply of the heater must
be disconnected. It is not enough
75 mA
to switch the heater off at the
control panel. Connecting under
power can destroy the time-
switch and the heater-electronics!
In commercial vehicles which
transport dangerous goods
according (GGVS/ADR) the
use of a time-switch is not
permitted.
The timer switch is to be installed
in the commercial vehicle format
(Art. no. 39890-00), either in the
apertures provided for in the
dashboard (page 4; fig. A) or
with an installation frame (fig. B)
at a suitable location.
In the camping design format
(Art. no. 39891-00 or 34042-01
respectively), installation is
effected with an installation