Waeco SinePower MSI912 Instrucciones De Montaje página 61

Ocultar thumbs Ver también para SinePower MSI912:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 89
SinePower
Overvoltage shutdown
Device
MSI912, MSI1312,
MSI1812, MSI1812T
MSI924, MSI1324,
MSI1824, MSI1824T
Undervoltage shutdown
Device
MSI912, MSI1312,
MSI1812, MSI1812T
MSI924, MSI1324,
MSI1824, MSI1824T
Excess temperature shutdown
Internal temperature
Shutdown
60 °C
Approvals
The device has E13 certification.
E
In compliance with the EMC directive 2004/108/EC including 2009/19/EC
and the Low-voltage Directive 2006/95/EC
 EN55012: Class B
 EN55014:Class B
 EN61000-6-1/6-3: Class B
 EN61000-6-2/6-4: Class A
 EN61204-3
EN
Shutdown
16 V
32 V
Undervoltage
warning
11 V
22 V
Restart
40 °C
Overvoltage
Restart
14.5 V
Undervoltage
Shutdown
10.5 V
21 V
Temperature on cooling element
Shutdown
95 °C
Technical data
29 V
Restart
12.5 V
25 V
Restart
<80 °C