trOuBLeshOOtiNg
Problem
The product
does not turn
on.
Unusual
noises during
operation.
teChNiCAL dAtA
Operating voltage:
Power input:
Protection class:
Water tank capacity:
Weight:
description
Maximum fan flow rate
Fan power input
Service value
Standby power consumption
Seasonal electricity consumption
Fan sound power level
Maximum air velocity
Measurement standard for service value
OAC100_A5_131106 (1.5).indb 33
Cause
Plug is not connected.
Power switch at position O.
Air vents are closed.
Air inlet filter and/or hose filter are
clogged.
Cooling function is active and tank is
empty.
220 – 240 V~, 50 Hz
80 W
II
20 litres
6.6 kg (without water)
33
solution
Connect plug to power
outlet.
Power switch to position i
(located on the side of the
product).
Open air vents.
Clean filter(s).
Fill water tank.
symbol
Value
F
5.04
P
61.97
SV
0.08
P
0.43
SB
Q
20.31
L
59.43
WA
c
Commission regulation (EU) No 206/2012
ISO 5801:2007
EN 50564:2011
EN 60704-2-7:1998
EN 60704-1:2010
eN
unit
m
/min
3
W
(m
/min)/W
3
W
kWh/a
dB(A)
1.40
metres/sec