8. Servicing
Your seca scale leaves the factory with an accuracy greater than ±0,1 %/±100 g. To en-
sure that this accuracy is maintained, the product must be carefully set up and regularly
maintained. Depending on the frequency of use, we recommend servicing every 3 to 5
years. Please ensure that a qualified service agent is used. If in doubt, contact seca Cus-
tomer Service for further information.

9. Technical data

Maximum load
Minimum load
Graduations
Dimensions
height:
width:
depth:
Height of figures
Weight
Temperature range
Power supply
Batteries
Power consumption
EN 60 601-1:
medical electrical equipment type B:
Accuracy
Functions
10. Disposal

Disposing of the device

Do not dispose of the device in
domestic waste. The device must
be disposed of properly as elec-
tronic waste. Follow the national regula-
tions which apply in your case. For further
information, contact our service depart-
ment at: service@seca.com
Model 952
200 kg / 440 lbs / 31.5 st
1 kg
100 g / 0.2 lbs
920 mm
565 mm
810 mm
20 mm
approx. 24.5 kg
+10 °C to +40 °C
batteries
6 type AA 1.5 V batteries
approx. 25 mA
greater than ±0,1 %/±100 g
Switch between units, NET, Auto-hold
Batteries
Do not throw used batteries away in do-
mestic waste. Dispose of batteries at col-
lection points in the vicinity. When buying
new batteries, select those low in harmful
substances and containing no mercury
(Hg), cadmium (Cd) or lead (Pb).