CONTROL UNIT PERGOLA TILT IO
2. 5. 2. Restoring the original configuration
Clearing the memory completely:
Press the PROG button on the circuit board for more than
7 seconds until all the indicator lights on the circuit board
light up.
2. 5. 3. Adding or deleting a control point from another control point
Control point 1: io control point 1 already programmed at the outputs concerned which will not be cleared.
Control point 2: io 2 control point to be programmed or cleared
at the same outputs as transmitter 1.
Β
⚠
On the io Situo 1 or io Situo 5 control points: Transmitter 2
may be a different channel with the same remote control
as transmitter 1.
Press the PROG button on the back of io control point 1 for
1)
more than 2 seconds until the motorised product makes up
and down movements on the output concerned.
Briefly press the PROG button on the back of the io control
2)
point 2 until the motorised product makes up and down
movements on the output concerned.
Β
⚠
The procedure to program or clear an io sensor is the same.
2. 6. TIPS AND RECOMMENDATIONS FOR INSTALLATION
2. 6. 1. Questions about the Pergola Tilt io Control Unit?
Observations
The motorised product
does not operate.
Copyright
2017 SOMFY ACTIVITES SA, Société Anonyme. All rights reserved.
©
-
OUTPUT Vdc
-
S1
Possible causes
The wiring is incorrect.
The drive is hot.
An incorrect cable has been used.
The control point is not compatible. Check for compatibility and replace the
1)
+
POWER SUPPLY
+
-
+
-
+
OUTPUT Vdc
OUTPUT Vdc
2)
Check the wiring and modify it if
necessary.
Wait for the motor to cool down.
Check the cable being used and make
sure that it has 4 conductors.
control point if necessary.
-
+
OUTPUT Vdc
POWER SUPPLY
-
+
-
+
-
+
-
S2 +
S1
> 7 s.
OUTPUT Vdc
OUTPUT Vdc
PROG.
1 2
4 3
-
S2 +
> 2 s.
PROG.
Solutions
EN
23