Disconnect the machine from the gas (if applicable) and electric mains and ensure utilities cannot be switched on again in error.
Connect the flow meter to a 3/4" stopcock. See Fig. 1.
Connect the water intake hose or Y-piece to the flow meter. See Fig. 2.
Note
PW 6107, PW 6137, PW 6167, PW 6207
Remove the screws on the left and right of the top of the lid.
Lift the front of the lid slightly, slide it to the rear and thus release the centring cones at the rear of the lid from the connection
strip.
Remove the lid upwards.
Break out the pre-punched area in the machine rear panel.
Fit the cable throughfeed on the rear panel.
Connect the flow meter connection cable in accordance with the wiring diagram "PW 6107-6207 module 7".
Refit the machine lid.
Note
PW 6101, PW 6131, PW 6161, PW 6201
Remove the cover plate from the electrical connection on the rear of the machine.
Connect the flow meter connections in accordance with the multifunction module 07 wiring diagram.
Refit the cover plate over the electrical connection on the rear of the machine.
Note
PW 6163, PW 6243, PW 6323
Remove the cover plate from the electrical connection box.
Connect the flow meter connections to the terminal strip in accordance with the wiring diagram.
Refit the cover plate on the electrical connection box.
Check the newly fitted parts for leaks.
Carry out appropriate safety checks.
Reconnect the machine to the electrical supply and, if appropriate, the gas supply. Switch the utilities on.
Activate flow meter measuring for the appropriate flow meter (here e.g. number 1) for the control via the service mode.
Via Service level main menu
button (on Flow meter 1 level: Yes)
Note
From ID 1000/1001, manual data backup must also be carried out as follows:
Carry out a data backup via the service mode.
Via Service level main menu
Activate disk symbol to overwrite BAE data.
To quit the service mode, switch off the machine.
Carry out a functional check, e.g. with the start of a programme. This programme should take in water via the appropriate flow meter.
If the machine display does not indicate a fault, the flow meter is in order.
en
15.08.2011
Diese Unterlagen dürfen ohne unsere Genehmigung weder vervielfältigt noch Dritten zugänglich gemacht werden. Eigentumsrechte vorbehalten.
Service settings
Basic settings
Back button (to revert 1 level)
Backup
Backup data to BAE (selection-display module)
Umbau- und Montageanweisung
Water intake
Flow meter
Flow meter 1: No
Activate disk symbol to save activation of flow meter 1.
M.-Nr. 06258812
Yes
OK
Overwrite existing data?