Reassembly for high performance
filter
Connect high performance filter. At this time, make
1.
sure to twist high performance filter so that securing lip
is firmly locked into cleaner unit.
► Fig.26: 1. High performance filter 2. Securing lip
► Fig.27: 1. Securing lip
2.
Connect capsule. Align O symbol on capsule with
O symbol on handle and then firmly twist capsule in
direction of arrow until it is secured.
► Fig.28: 1. O Mark
► Fig.29: 1. Handle 2. Capsule
NOTE: Always remove dust ahead of time, as suction
power will be reduced if there is too much dust in
cleaner.
NOTE: Always be sure to check that high perfor-
mance filter is loaded correctly prior to using cleaner.
If they are not loaded correctly, dust will get into the
motor housing, and cause motor failure.
If the following examples occur, high performance
filter is not loaded correctly. Reload them correctly to
rectify problem.
Problem Examples
Securing lip of high performance filter is not firmly
locked into groove of cleaner housing.
► Fig.30: 1. Securing lip 2. Groove of cleaner housing
OPERATION
CAUTION:
To connect attachments, such
as nozzle, twist and insert the attachment in
direction of the arrow to secure the connection
during use. To disconnect the attachments, twist
and extract it also in direction of the arrow. If an
attachment is twisted in the opposite direction when
being connected or disconnected, the capsule may
become loose.
► Fig.31: 1. Capsule
Cleaning (Suction)
Nozzle
Attach the nozzle to clean off tables, desks, furniture,
etc. The nozzle slips on easily.
► Fig.32: 1. Nozzle
Nozzle + Extension wand (Straight
pipe)
The extension wand fits in between the nozzle and
the cleaner itself. This arrangement is convenient for
cleaning a floor in a standing position.
► Fig.33: 1. Cleaner body 2. Extension wand
3. Nozzle
Corner nozzle
Fit on the corner nozzle for cleaning corners and crev-
ices of a car or furniture.
► Fig.34: 1. Corner nozzle 2. Cleaner body
Corner nozzle +Extension wand
(Straight pipe)
In tight quarters where the cleaner itself cannot
squeeze in, or in high places hard to reach, use this
arrangement.
► Fig.35: 1. Corner nozzle 2. Extension wand
3. Cleaner body
Cleaning without nozzle
You can pick up powder and dust without nozzle.
► Fig.36
MAINTENANCE
CAUTION:
Always be sure that the tool is
switched off and the battery cartridge is removed
before attempting to perform inspection or
maintenance.
NOTICE:
Never use gasoline, benzine, thinner,
alcohol or the like. Discoloration, deformation or
cracks may result.
After use
NOTICE:
Putting the cleaner against the wall
without any other support cause the cleaner to
fall down and be damaged.
► Fig.37
Cleaning
From time to time wipe off the outside (cleaner body) of
the cleaner using a cloth dampened in soapy water.
Clean out also the suction opening, dust bag/paper filter
mounting area and the dust stopper.
► Fig.38
Wash the filter in soapy water when it is clogged with
dust and the cleaner power becomes weak. Dry it out
thoroughly before use. An insufficiently dried filter may
cause poor suction and shorten the service life of the
motor.
► Fig.39