Installation Ric T40D - T60D; Fitting The 90° Manifold (Accessory) - Rico Ric T40D Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 63
To avoid overloads caused by pressure fluctuations, install a bypass pressure-relief valve on the suction
pipe in case of operation as an exhauster, and on the delivery when operating as a blower.
If the flow rate has to be reduced, use a bypass valve instead of throttling the suction or delivery.
Protect the suction pipe with a filter with max. degree of filtration 25µm. For the use of filters with filtration
different from 25µm, ask Rico. Foreign bodies are: dust, sand, gravel, dirt in the pipes, cutting burrs and
shavings, welding slag and spatter, metal burrs and sealant residuals produced when connecting the pipes.
Change the filters regularly.
Size the pipes and choose accessories that minimise pressure losses; therefore:
do not fit pipes narrower than the ports of the machine.
when installing several machines in parallel, suitably size the manifold and the main line.
use large-radius curves and not elbows.
do not install valves with a smaller flow than nominal and check valves with shutter opposed by spring (the check valve with
lowest pressure loss is the lightened non-return valve).
when used for oxygenation, choose diffusers with low flow resistance (low pressure loss).
Danger due to foreign bodies and dirt entering the unit!
The ingress of even tiny foreign bodies causes serious damage to the unit with probable breakage of the impeller blades and the danger
of debris being thrown out!
See INSTALLATION DIAGRAMS in the first section.
INSTALLATION RIC T40D – T60D
12.2
Units supplied with standard set-up are ready to be installed in
the horizontal position by means of the feet.
The feet have holes for fixing; use all the holes and
choose the appropriate type of screw.
Remove the protection on the ports before checking the
rotation direction and before final connection.
To connect the unit to the piping, remove the flanges from the
silencer housings to make the appropriate connections using
flexible sleeves, thereby avoiding rigid connections which can
cause stress and harmful vibrations.
Refit the flanges on the silencer housings complete with
gaskets and tighten.
NOTE FOR THE USER
12.2.1
Fitting the 90° manifold (accessory)
Undo the manifold screws.
Undo the silencer housing screws.
Place the gasket on the blower inlet port.
Screw the silencer housing on the manifold.
Screw the manifold with silencer housing on the blower inlet
port, choosing the desired position.
See silencer housing repositioning diagrams in the first section.
 Druckluftanlagenbau GmbH
RIC T40D – T120D
The position of the silencer housing can be changed by using the manifold CK (on request).
See silencer housing repositioning diagrams in the first section.
Tel. +49 ( 0 ) 2151 9931 99 -
vk@rico-druckluft.com
-
www.seitenkanalverdichter.de
37 / 117