1St Level Programming - O&O CSB-BR Manual De Instalacion Y Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

The following table gives the 1st level functions and the single settable parameters.
= DEFAULT value set in factory.
Par
Function
Selects the functioning logic.

(see notes after the table)
Close input confi guration

(see notes after the table)

Photocells

Encoder

Warning fl ash

Arm lights
Pause time

(expressed in seconds)
Resetting default parame-

ters. (see notes after the
table)

Exiting the menu/saving
Description of level 1 parameters

·
: Functioning logic
- Hold-to-run: The automation works when the commands are held down. The start command opens once and closes once.
- Semi automatic: The automation works with jog commands, without automatic reclosing. Hence, when fully open, to control
closing you need to act on the start or close command respectively.
- Automatic: The automation works in jogs. When the opening manoeuvre is completed in the standard cycle, automatic
reclosing is activated after the pause time set (parameter ).

·
: Close confi guration
:
-
Close-when-released input
This mode has been developed so the arm closes automatically only when the vehicle has completely passed by the
photocell or magnetic detector (the most suitable accessories for this purpose). Connect the N.O. contact of the detector or
photocell to the Close contact terminals.
If the vehicle is on the detector or in front of the photocell it does not cause immediate closing but rather you have to wait
for the signal to be released.

-
: The close command acts as a release closing and safety function.
When closing, the close command engaging stops the automation. When disengaged the barrier resumes closing.
6.2
1ST
LEVEL PROGRAMMING
: Hold-to-run
: Semi automatic
: Automatic
: Standard close input
: Close-when-released input
: The close command acts as a release closing and safety function.
: When closing it stops and waits for disengaged photocell commands
: When closing it stops; reclosing after 1'' when the photocell is disen-
gaged
: When closing it reopens; reclosing after 1'' when the photocell is
disengaged
: When closing it reopens; reclosing after 5'' when the photocell is
disengaged
: When closing it reopens; reclosing when the photocell is disengaged
: When closing it reopens and waits for disengaged photocell com-
mands
: Excluded
: When closing it stops and waits for commands
: When closing it reopens and waits for commands
: When closing it reopens, reclosing after 5 seconds
: Excluded
: Prior to each movement on a confi gured output (see parameters
,, in the 2nd level table)
: Prior to each movement on a confi gured output and on the arm lights
: Flashing when moving, off when the arm is closed and open
: Flashing when moving and on when the arm is closed
: Flashing when moving and with the arm closed, on when the arm is
open and when stopped
-
: No resetting
: Resetting the default parameters.
Exit programming and view machine statuses
(see notes St automation statuses display)
- 20 -
= parameter value set during installation: must be indicated if
DEFAULT value is modifi ed.
Settable data









Publicidad

Tabla de contenido
loading

Productos relacionados para O&O CSB-BR

Este manual también es adecuado para:

Csb-spCsb-xt

Tabla de contenido