Operation Modes - EHEIM PRESS 10000 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 29
English
4.
Commissioning
Installing the closing cover (⌦A)
1. Insert the sealing washer ② into the closing cover ①.
2. Screw the closing cover onto the screw connection DIRTY.
Installing the pump connection (⌦A)
3. Connect the spiral hose of the pump to the connecting piece ③.
4. Insert the sealing washer ⑤ into the union nut ④.
5. Screw the connecting piece onto the screw connection IN with the union nut.
Connecting the outlet hose (⌦B)
6. Connect the spiral hose for the outlet to the connecting piece ⑥.
7. Insert the sealing washer ⑧ into the union nut ⑦.
8. Screw the connecting piece onto the screw connection OUT with the union nut.
We recommend fastening the hoses with hose clamps
5.

Operation modes

The following operation modes can be selected via the control dial:
WORK (⌦C)
Hose connection IN - connection of pump
Hose connection OUT - outlet in the pond
Pond water is pumped into the filter by the pump and, when filtered, fed back into the pond.
CLEAN (⌦D)
Hose connection IN - connection of pump
Hose connection DIRTY - wastewater outlet
The filter can be cleaned in this operation mode. Pond water is also pumped through the filter in reverse direc-
tion and fed through the wastewater outlet.
6.
Operation
Caution!
▶ Heed the operating manual for the pump, especially the chapters on safety, commissioning and
operation!
1. Place the filter on the pond bank or partially bury it (⌦E).
2. Place the pump on a solid surface as horizontal as possible in the pond so that the filter housing
of the pump is covered by at least 20 cm of water. Pay attention to the maximum pond depth (see
Technical data).
13

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Press 7000

Tabla de contenido