Setting up and connecting the appliance
7.2
Notes on installing the appliance
A
NOTICE!
• Ensure that the ventilation slots remain clear during the installation.
Obstructed ventilation slots lead to increased power consumption
and can damage the appliance.
• Waste heat produced by the appliance must be extracted via a ven-
tilation shaft on the rear.
• The ventilation shaft must have cross-section of at least 200 cm
• Ensure that the power cable is not jammed when pushing the appli-
ance into place.
• The plastic seals included are mounted to seal right and left between
the appliance and the kitchen unit.
S16FG and S40FGD can be installed in a kitchen unit under the counter.
S117FG can be installed in a kitchen cabinet.
Installing S16FG and S40FGD (fig. f, page 4)
➤ Observe the installation dimensions (in mm):
S16FG
S40FGD
➤ When using skirting board:
Ensure that ventilation openings in the skirting board have a cross-section of at
2
least 300 cm
.
Installing S117FG
➤ Observe the installation dimensions (in mm):
S117FG
16
Width
300
600
Width
600
Depth
min. 575
min. 575
Depth
min. 575
MaCave
2
.
Height
822 – 892
822 – 892
Height
1770
EN