Special instructions: Replacing the depot and work on the CO ² Armatur Pro must only be carried out when the device is pressureless
CO ² Armatur Pro technical data:
Gas type:
connection number:
Operating pressure:
Pressure gauge connection:
Valve spindle:
Illustrations are non­binding. Technical details are subject to change.
Assembly a CO ² Solenoid Valve Pro: The CO ² Solenoid Valve Pro is screwed between the fitting and the needle valve
the needle valve from the needle valve. Then connect the needle valve to the connecting screw of the CO ² Solenoid Valve Pro
is essential that you wrap the outer thread of the connections with 4 – 5 layers of Teflon tape
100 % tightness. Then screw the completely assembled CO ² Solenoid Valve Pro into the fitting
and check the threaded connections for tightness!
CO ² Solenoid Valve Pro technical data:
Voltage:
230 V
Max. Pressure:
0 – 3 bar
Power consumption:
2 W
2
6
CO ² , connection according to DIN 477 Part 1
6
0 – 3 bar
2 x G 1/4"
stainless steel
1
3
Hose union output:
Thread:
3
7
Connections:
output for CO ² hose
Microfilter:
2 units installed
Material:
nickel­plated brass
Weight:
approx. 960 g
. Remove
1
(included in the delivery) to ensure
2
. Align the CO ² Solenoid Valve Pro
4
2
4
4/6 mm CO ² hose
closed when currentless
4
8
. It
3
5