Descargar Imprimir esta página

Villeroy & Boch 34 234 969-FF Instrucciones De Montaje página 34

Publicidad

US Operating conditions
Cold water temperature
Hot water temperature
Recommended hot water
temperature
Thermal disinfection (5:00 mins.)
Permissible flow pressure
Recommended flow pressure
Large differences in pressure between cold and
hot water supply must be balanced.
The customer has to provide a pressure
reducer in the main line downstream of the
water meter to comply with the noise levels
according to the noise class at a resting
pressure above 500 kPa / 73 psi / 5 bar.
If combined with continuous-flow heaters, the
minimum flow volume of the safety shut-off has
to be considered.
Observe the manufacturer's instructions for the
continuous-flow heater.
34
SE Driftsförhållanden
41 – 77 °F
Kallvattentemperatur
131 – 149 °F
Varmvattentemperatur
Rekommenderad
140 °F
varmvattentemperatur
≤ 158 °F
Termisk desinfektion (5:00 min.)
15 – 73 psi
Tillåtet flödestryck
45 psi
Rekommenderat flödestryck
Större tryckdifferenser mellan kall- och
varmvattenförsörjningen ska balanseras.
En trycksänkare ska monterats in i
huvudledningen efter vattenmätaren för
överensstämmelse med bullervärdena vid ett
vilotryck över 500 kPa / 73 psi / 5 bar.
Vid en kombination med
genomströmningsberedare ska den minsta
flödesmängden för säkerhetsavstängningen
beaktas.
Följ anvisningarna från tillverkaren av
genomströmningsberedaren.
5 – 25 °C
55 – 65 °C
60 °C
≤ 70 °C
1 – 5 bar
3 bar

Publicidad

loading

Este manual también es adecuado para:

34 457 969-ff