Puls Dimension UBC10.241 Manual De Instrucciones página 4

Fuente de alimentación sin interrupciones

Publicidad

UBC10 Instruction Manual
Ready (1-2)
Buffering (2-3)
Replace Battery (5-6)
Inhibit (7-8)
Fig. 1 / Bild 1
ON
OFF
ON
OFF
ON
OFF
Dimensions / Abmessungen
PU-357.011.05-10C (2016-02)
User Interface
A Power Port
Quick-connect spring-clamp terminals, for input voltage and output
voltage.
B Signal Port
Plug connector, inserted from the bottom. Connections for the
Ready, Buffering, Replace Battery relay contacts and for the Inhibit
input.
C Green Status LED (see Fig. 1 for LED pattern)
Ready: Battery is charged, no wiring failure is recognized, input
voltage is sufficient and inhibit signal is not active.
Charging: Battery is charging and the battery capacity is below
85%.
Buffering: Unit is in buffer mode.
D Yellow Diagnosis LED (see Fig. 2 for LED pattern)
Overload: Output has switched off due to long overload in buffer
mode or due to high temperature.
Replace battery: Indicates a battery which failed the battery quality
test (SoH test). Battery should be replaced soon.
Buffer-time expired: Output has switched off due to setting of
Buffer-timer Limiter. This signal will be displayed for 15 minutes.
Inhibit active: Indicates that buffering is disabled due to an active
inhibit signal.
E Red Check Wiring LED
This LED indicates a failure in the wiring, battery, battery fuse or
installation (e.g. too low input voltage).
F Buffer-time Limiter
This dial limits the maximum buffer time during a buffer event to
save the battery energy, for a faster recharge and to expand the
battery life.
Contact is closed when battery is charged and unit is ready to buffer.
Contact is closed when unit is buffering.
Contact is closed when a replacement of the battery is necessary.
Buffering is disabled when an voltage > 10V is applied to the pins.
Relay contact rating: max. 60Vdc 0.3A, 30Vdc 1A, 30Vac 0.5A
resistive load; min. 1mA at 5Vdc; 500Vac insulated to the power port.
Fig. 2 / Bild 2
ON
OFF
Ready
ON
OFF
Charging
ON
OFF
Buffering
ON
OFF
UBC10 Bedienungsanleitung
Benutzer Schnittstelle
A Leistungsanschlüsse
B Signalanschlüsse
C Grüne „Status" LED
D Gelbe „Diagnosis" LED (Blinkmuster ist in Bild 2 erklärt)
Rote „Check Wiring" LED
F "Buffer-time Limiter"
Kontakt ist geschlossen wenn die DC-USV geladen und pufferbereit ist.
Kontakt ist geschlossen wenn das Gerät im Pufferbetrieb ist.
Kontakt ist geschlossen wenn ein Austauschen der Batterie erforderlich
ist.
Wenn eine Spannung > 10V anliegt ist eine Pufferung nicht möglich.
Belastbarkeit der Relaiskontakte: max. 60Vdc 0.3A, 30Vdc 1A, 30Vac
0.5A Widerstandslast; min. 1mA bei 5Vdc;
Wiring diagram / Anschlussdiagram UBC10.241
Overload
Replace
Battery
Buffer time
-
expired
24V
Inhibit
active
Power
supply
N
L PE
Functional Diagram / Funktionsschaltbild
DC-UPS Control unit with integrated battery
Input Fuse
+
&
24V
Power
Input
Reverse
Supply
Polarity
-
Protection
Battery Charger
&
Tester
12V 5Ah battery
-
*) Return current protection: This feature utilizes a MOSFET instead of a diode to minimize power losses.
The information in this document is believed to be accurate and reliable and may change without notice.
Federkraftklemmen für die Eingangs- und Ausgangsspannung.
Steckverbinder von unten einsteckbar. Anschlüsse für die Ready,
Buffering, Replace Battery Relaiskontakte und für den Inhibit Eingang.
(Blinkmuster ist in Bild 1 erklärt)
Ready: Die DC-USV ist pufferbereit. Batterie ist geladen, kein Inhibit
Signal, kein Verdrahtungsfehler, Eingangsspannung ist ausreichend.
Charging: Die Batterie wird geladen und hat einen Ladezustand von
weniger als 85%.
Buffering: Die DC-USV ist im Pufferbetrieb.
Overload: Meldet einen abgeschalteten Ausgang, aufgrund von
Überlast während des Pufferbetriebes oder Übertemperatur.
Replace battery: Meldet, wenn die Batterie den Qualitätstest nicht
besteht. Batterie sollte baldmöglichst ersetzt werden.
Buffer-time expired: Meldet einen abgeschalteten Ausgang,
aufgrund von abgelaufener Pufferzeit (Buffer-Time-Limiter). Die
Meldung wird gespeichert und 15 Minuten lang angezeigt.
Inhibit active: Ein aktives Inhibit Signal verhindert eine Pufferung.
Meldet eine notwendige Überprüfung der Verdrahtung zwischen DC-
USV und Batterie sowie eine notwendige Überprüfung der Batterie
selbst. Meldet auch, wenn die Eingangsspannung zu klein ist.
Mit diesem Einstellregler lässt sich die Pufferzeit begrenzen um die
Batterie zu schonen, und eine schnellere Nachladung zu erreichen.
Fig. 3 / Bild 3
-
-
-
-
24V
24V
IN
OUT
Unbuffered
Buffered
load
load
DC-UPS
UBC10.241
Electronic
*
Current
Limiter
Step-up
Converter
Controller
Cut-off
Relay
(1)
(2)
(5)
(6)
(3)
(4)
Ready
Buffering
Replace
Fuse
Contact
Battery
Contact
Contact
isoliert mit 500Vac.
24V
unbuffered
branch
24V
buffered
branch
+
Buffered
Output
Load
-
Status LED (green)
Diagnosis LED (yellow)
Check Wiring LED (red)
Buffer-time Limiter
10s, 30s, 1m, 3m, 10m,
(7)
Inhibit +
(8)
Inhibit -

Publicidad

loading

Este manual también es adecuado para:

Dimension ubc10.241-n1