Function Setting - REDWALL V serie Instrucciones De Instalación

Ocultar thumbs Ver también para V serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

5

FUNCTION SETTING

Applicable
SIP-5030
models
Far area sensitivity selector
switch
Walk tester
connector
Sens.Select.SW.
Sens.Select.SW.
5730980
5730980
Far area
Far area
Near area
Near area
Creep zone
Creep zone
Alarm
Alarm
Creep
Creep
UP DWN
Operation indicator
(See Step 11.)
Cautions>>
If the red LED keeps blinking for approx. 0 seconds
after turning the power on, turn the power off and then
on again.
Applicable
SIP-5030
models
Far area sensitivity selector
switch
Walk tester
connector
Sens.Select.SW.
Sens.Select.SW.
5730980
5730980
Far area
Far area
Near area
Near area
Creep zone
Creep zone
UP DWN
Far
Far
Near
Near
Creep
Creep
Operation indicator
(See Step 11.)
Cautions>>
If the red LED keeps blinking for approx. 0 seconds
after turning the power on, turn the power off and then
on again.
5-1
Sensitivity Selector Switch for Far
Area, Near Area and Creep Zone
Applicable
SIP-5030
models
You can change the sensitivity for far area
detection, near area detection and creep zone
detection independently.
SELECTOR
POSITION
Sens.Select.SW.
Sens.Select.SW.
SH
H
Far area
Far area
Near area
Near area
Creep zone
Creep zone
M
(Factory
default)
L
SIP-100
Near area sensitivity
selector switch
Creep zone
sensitivity selector
switch
Sens.Select.SW.
Sens.Select.SW.
5730980
5730980
Far area
Far area
Near area
Near area
Creep zone
Creep zone
Alarm
Alarm
Creep
Creep
UP DWN
1:
Detection logic selector
(AND or OR)
2:
Setting invalid
3,4: Alarm holding time selectors
SIP-100
Near area sensitivity
selector switch
Creep zone
sensitivity selector
switch
Sens.Select.SW.
Sens.Select.SW.
5730980
5730980
Far area
Far area
Near area
Near area
Creep zone
Creep zone
UP DWN
Far
Far
Near
Near
Creep
Creep
1:
Detection logic selector
(AND or OR)
2:
Number of Outputs selector
switch
3,4: Alarm holding time selectors
SIP-100
FUNCTION
Suitable for sites requiring a level
of sensitivity higher than "H"
Suitable for sites requiring a level
of sensitivity higher than "M"
Suitable for standard applications
Suitable for hostile and narrow area
5-2
Detection Logic Selector Switch
Applicable
models
Tamper
switch
UP
DWN
5-3
Number of Outputs Selector Switch
Applicable
models
UP
Tamper
switch
DWN
Cautions>>
When you output far area alarm with Number of Output
Selector Switch, far area detection area depends on the
main unit installation height.
Detection area is approximately 35-100m for 4m (13ft.)
installation height and 20-100m for 2.3m (.ft.) installation
height.
5-4
Alarm Interval Switch
Applicable
models
-  -
SIP-5030
Detection area of SIP-5030 and SIP-100 consist
of two types of plane detection areas in an
alternative manner constructed by two pairs of
pyro-elements (quad element for the far area),
for the near area, far area and the creep zone.
SELECTOR
STATUS
POSITION
A sensor signal is output when an
object is detected in either of the two
OR
detection areas.
(
)
UP
Factory
* Use this mode when you adjust
default
the detection area. Switch to AND
mode after you have finished the
detection area adjustment.
Use this mode to reduce instances
of incorrect detection of objects. The
sensor signal is output only when
DWN
AND
an object is detected within the two
detection areas. If any objects are
blocking multiple detection areas,
use OR mode.
SIP-5030
SELECTOR
STATUS
POSITION
SIP-5030
UP
3
Setting invalid.
DWN
(
)
Factory
2
Setting invalid.
default
SIP-5030
You can set an interval (4 different times) to
suspend the alarm signal output.
For example, if you set this interval to 30
seconds, no more alarm signals will be output
for 30 seconds after the output of the first alarm
signal. If no pedestrians are detected for more
than 30 seconds, the system returns to the
standby mode.
Then, when a pedestrian is detected, the alarm
signal will be output.
SELECTOR
POSITION
0 sec
(Factory
FUNCTION
default)
1
Dip switch
SIP-100
FUNCTION
2
Dip switch
SIP-100
FUNCTION
SIP-100
The three alarms,
which are far area, near
area and creep zone
are output separately.
The two alarms, which
are far/near area and
creep zone are output
separately.
3-4
Dip switch
SIP-100
15 sec 30 sec 0 sec

Publicidad

Tabla de contenido
loading

Productos relacionados para REDWALL V serie

Este manual también es adecuado para:

Sip-5030Sip-100

Tabla de contenido