7.2
Mounting the gas detector
Note the following when selecting a place to fit the gas detector:
Note the length of the cable.
The gas detector should be mounted in the vicinity of the sleeping area at the height of
the mattress.
➤ Select a suitable installation location.
A
NOTICE!
Before making any drill holes, ensure that no electrical cables or other parts
can be damaged by drilling.
➤ Hold the mounting panel on the chosen location and mark the two drill holes (fig. 5,
page 5).
➤ Screw the mounting panel tight with the two self-tapping screws (fig. 6, page 5).
➤ Insert the gas detector on the mounting panel (fig. 7, page 5).
➤ Insert the plug of the gas detector in the socket of your 12/24 Vg voltage supply.
✓ The green LED on the gas detector (fig. 8 1, page 5) flashes for approx. 10 min.
The sensor is then brought to the operating temperature.
When the green LED glows constantly, the gas detector is ready for operation.
8
Connecting the gas detector
8.1
As a single device
If you use the gas detector as a single device, you can either
Switch it on with the 12/24 Vg plug
Switch it on with the RV-AMP-SW additional switch (accessory), if there is no
12/24 Vg socket in the sleeping area.
Connecting the gas detector using the 12/24 Vg plug
➤ Insert the 12/24 Vg plug into a socket with a constant 12/24 Vg supply.
This socket should be connected with the vehicle battery.
✓ An acoustic signal sounds and the green LED (fig. 8 1, page 5) flashes for approx.
10 minutes.
During this time the gas detector conducts a system test and the sensor is brought to
operating temperature.
EN
Connecting the gas detector
25