17 Troubleshooting

This chapter provides you with important notices with regard to operating the device.
Observe the following notices to avoid dangers and damages:

17.1 Safety notices

Attention
► Only qualified electricians, who have been trained by the manufacturer, may carry out
any repairs on electrical equipment.
► Improperly performed repairs can cause considerable dangers for the user and
damages to the device.

17.2 Fault indications

In the event of a fault, an error code will appear in the display; it describes the cause of the
fault. The following table assists in localizing and rectifying minor faults.
Fault
Possible Cause
Waiting status
- - -
Electronic control of low
E01
voltage. (<140V)
Electronic control of excess
E02
voltage (>260V)
IGBT short circuit.
E03
E04
IGBT overheating protection
Overheating protection on
E05
power mode (>150°C)
Temperature sensor
E06
problem or short circuit
E07
Technical defect
+E08
► If error messages continue to be displayed after an extended waiting period or after
restarting the appliance, then it must be sent to Customer Service to be examined.
To Rectify
Place a suitable pot/pan onto the induction
cooking field. The plate will work as usual
Make sure the appliance is connected to the
voltage indicated on the rating label.
Please send back to customer service.
Eliminate the course of overheating. Once the
cooktop has cooled, the appliance can be put into
operation again.
Eliminate the course of overheating. Once the
cooktop has cooled, the appliance can be put into
operation again.
The temperature sensor underneath the glass
ceramic plate is defective. Please send back to
customer serivce.
Please send back to customer service.
Please note