Water connections
All inlet connections to the machine are to be fitted with manual shut-off
valves and filters, to facilitate installation and servicing.
NOTE:
The inlet filter screens are provided inside the machine's
connection fittings.
Water pipes and hoses should be flushed clean before installation. After
installation, hoses should hang in gentle arcs.
Hoses are to be of an approved type and grade, to comply with national
regulations.
The machine has two DN 20 (R 3/4") water garden hose water connections.
Both inlets on the machine must be connected to the water supply, or the
machine may not function properly.
Your water heater should supply hot water at a minimum temerature of 120
degrees Fahrenheit (49 degrees Celsius) and a maximum of 170 degrees
Fahrenheit (77 degrees Celsius).
The required water pressure is as follows:
min:
•
max:
•
recommended: 30-90 PSI (200-600 kPa)
Installation
15 PSI (100 kPa)
90 PSI (600 kPa)
3:1