GB
5. Technical data
Operating voltage
Power consumption
Current consumption
Protection class
Maximum delivery capacity
Maximum discharge head
Noise level
Float switching points
Potential-free contact
Minimum ambient temperature
Maximum medium temperature
Resistance to acids
Overheating protection
Dimensions L x W x H
Tank volume
Weight
6. Characteristic curve and installation arrangement (see fig. 3, page 3)
7. Assembly
The pump is designed exclusively for operation in dry interior rooms
Warning
(air temperature not higher than 60 °C).
The pump and the entire conveying hose must be protected against frost!
Care must be taken to ensure that the pump is installed horizontally! (see fig. 4, page 3)
Warning
Secure footing is to be ensured if mounted on the floor.
Installation in potentially explosive areas is not permissible!
The pressure hose for the discharge of the condensate is to be pushed onto the non-
return valve up to the stop. The non-return valve can simply be screwed out in order
to fit the pressure hose. Subsequently, lock the non-return valve again with a quarter
turn in the clockwise direction.
The maximum radius of curvature of the pressure hose is 50 mm. The pressure hose
may not be squeezed or pinched off.
10
characteristic curve / assembly
230 V, 50-60 Hz
75 W
0,80 A
IP54 / Class B
400 l/h
3,7 m
43 dB(A) at a distance of 1 m
On: 27 mm, off: 21 mm, alarm: 32 mm
N.C., switching voltage 24 - 250 V
> 0°C (frost-protected)
65 °C (short-term 80 °C)
pH 2 or higher
120 °C (autom. restart after cooling)
190 x 80 x 100 mm without tank
225 x 100 x 105 mm with tank
0,5 l
1,8 kg
Technical data /
3062692_201208