AXIS Q8108-R User's Guide
Start up and shut down
The AXIS Q8108-R starts up automatically when power
is supplied. See AXIS NVR Manager, on page 13 for
more options. The AXIS Q8108-R automatically does a
controlled shut down after one minute when the power
is shut off.
Internal power button
Use this button to manually start up or shut down the AXIS Q8108-R. When pushed briefly the NVR
will power down in a controlled manner, which will take 15 - 30 seconds. If the button is held down
for more than 3 seconds the NVR will hard power down. This is useful if for some reason the NVR
becomes unresponsive.
The internal power button is also used for resetting the NVR to factory default settings, see
Resetting to the factor default settings.
Battery backup function
The AXIS Q8108-R has an Uninterruptable Power Supply (UPS) designed for short power shortages.
For periods more than 1 minute, the UPS will provide enough power to the AXIS Q8108-R for a
controlled shut down.
A controlled shutdown may not occur if the battery temperature is outside of charging
range
0 - 45°C (32 - 113°F)
Resetting to the factory default settings
This will reset parameters to the factory default settings including the password.
1. Disconnect power from the NVR and remove back cover.
2. Make sure all indicator LEDs are off (this could take a few moments).
3. Press and hold the Internal power button and reconnect power.
4. Release the Internal power button when the power LED is lit.
These settings will be reset:
•
Network configuration is set to factory default (DHCP and UPnP™ off)
•
Administrator password is set to "password"
•
Power Configuration is set to "Automatic"
Resetting the NVR to factory default settings will not affect AXIS Camera Station settings or
recordings.
.
Internal power button
Page 11