Technical data
Supply voltage
12 V
Current input
summer operation: 1,5 mA
winter operation with
defroster (EisEx): 160 mA
The Remote indicator complies
with the vehicle engine inter-
ference suppression directive
72/245/EEC with supplements
and bears type approval number:
e1 03 4352
Installation instructions
Only an expert technician
may install and repair the
remote indicator.
When using specific vehicle or
manufacturer control panels, the
electrical connection must be
in accordance with the Truma
interface description (part no.
50020-56600).
The electrical connec-
tion or the connection
to a cable extension must not
be effected in the cylinder
container!
For passing cables through a
cylinder container (9), use rubber
grommets or bodywork sealing
material. Establish the cable run
at least 50 cm above the base of
the cylinder container.
Replacing earlier remote indi-
cator versions with the DuoC
remote indicator.
When earlier versions of a re-
mote indicator are replaced with
the Truma DuoC remote indica-
tor, the connecting cable be-
tween the regulation system and
the control panel can be re-used
in accordance with the wiring
diagrams (see page 10).
9