EN
•
Switch the unit off when this level has been reached. If you require further use of the
steamer, ensure unit is switched off and has stopped boiling.
•
Wait for 5 minutes.
Beware of Steam! The Steam is very hot - wear gloves and keep face clear.
•
Slowly unscrew the cap, any remaining trapped steam will be released from beneath
the cap.
•
Refill to the MAX water level as before (Fig. 1, C) and follow above instructions.
You must never allow the unit to boil dry. There is a safety thermal cut-out
device fitted to the unit. If the unit is allowed to boil dry this will operate and
prevent further use.
•
Switch the unit off and allow it to cool for at least 5 minutes, refill with water and then
switch on again - the thermal cut-out should automatically reset.
•
If this has not reset allow a further cooling period.
13. Storage
•
When you have finished using the unit allow any remaining water to cool and then
empty the unit. We recommend flushing the tank out with clean water before storing.
Never leave water in the unit whilst being stored.
Storage Spools
•
The supply cord and hose must be fully unwound before commencing to operate the unit.
•
To recoil the supply cord, fit the plug into the socket-outlet on the side of the spool and
then wind the supply cord onto the spool.
•
To recoil the hose, place the steamplate end of the hose into the side aperture of the
spool and then wind the hose onto the spool (Fig. 1, E).
Storage Steamplate
•
The handle of the steamplate is shaped to locate between the frame and the tank.
•
Slide the steamplate into position with the handle against the tank and the thread
towards the base (Fig. 1, F).
Model
Boiler Capacity
LMB 230V
7.5L
LMB 110V
7.5L
*Approx. steam time before the safety cut-out operates.
10
Steam Time
80 -100 Minutes*
195 Minutes*
LMB