ELECTRICAL SPECIFICATIONS

1. All wiring must comply with local and national
electrical codes and must be installed by a
licensed electrician. If you have any questions
regarding the following instructions, contact a
licensed electrician.
2. Check available power supply and resolve any
wiring problems BEFORE installing and operating
this unit.
3. For your safety and protection, this unit is
grounded through the power cord when
plugged into a matching wall outlet. If you are
not sure whether your wall outlet is properly
grounded, please consult a licensed
electrician.
4. The wall outlet (3-pin) must match the plug
(3-pin) on the power cord supplied with the unit.
DO NOT use plug adapters or extension cords.
See (Table 1) for receptacle and fuse information.
5. The rating plate on the unit contains electrical
and other technical data. The rating plate is
located on the front of the base pan. Make sure
to use the correct power supply according to the
rating plate of your air conditioner.
COOLING CAPACITY
RATED VOLTS
AMPS
WALL OUTLET
FUSE SIZE
Note:8K-15K including
18K including AAW-18CR3FHUE AAW-18CM3FHUE
22K-24K including AAW-22CR3FHUE AAW-22CM3FHUE
3/2/05
12:13 PM
Page 8
RECEPTACLE AND FUSE TYPES
8K-15K
125
15
15
AAW-08CM1FHUE
AAW-08CR1FHUE
AAW-10CR1FHUE
AAW-10CM1FHUE
AAW-12CM1FHUE
AAW-12CR1FHUE
AAW-15CM1FHUE
AAW-15CR1FHUE
AAW-24CR3FHUE AAW-24CM3FHUE
Electric Shock Hazard
If the air conditioner has a serial plate rating
of 115 volts and up to and including 7.5 amps,
the unit maybe on a fuse or circuit breaker
with other devices. However, the maximum
amps on all devices for that fuse or circuit
breaker can not exceed the amps of the fuse
for the circuit breaker.
If the air conditioner has a serial plate rating
of 115 volts and greater than 7.5 amps it
must have its own fuse or circuit breaker,
and no other device or unit should be
operated on the fuse or circuit breaker.
If the air conditioner has a serial plate rating
of 230 volts, it must have its own fuse or
circuit breaker, and no other device or unit
should be operated on the fuse or circuit
breaker.
To avoid the possibility of personal injury,
disconnect power to the unit before installing
or servicing.
18K
250
15
15
6
!
22K-24K
250
20
20
Table 1