Technical Data - SATA air carbon Instrucciones De Servicio

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 71
Operating instructions SATA air carbon regulator
EN
[2-8]
Cap for SATA air warmer
carbon
Connection breathing pro-
[2-9]
tection hood

7. Technical Data

Description
Necessary operating pressure (regulator closed)
without SATA air warmer carbon
and without spray gun
without SATA air warmer carbon,
with spray gun (in combination
with 1.2 m spray air hose Art. No.
13870)
with SATA air warmer carbon and
without spray gun
with SATA air warmer carbon with
spray gun
Max. operating pressure
Required minimum volume flow
Maximum flow rate (6 bar, air regu-
lator open wide)
Operating temperature
Storage temperature
Max. tube length
Noise level (2.5 bar, air regulator completely closed)
without SATA air warmer carbon
with SATA air warmer carbon
Noise level (6 bar, air regulator completely open)
without SATA air warmer carbon
with SATA air warmer carbon
Weight air regulator carbon
without SATA air warmer carbon
with SATA air warmer carbon
Operating pressure of compressed
air safety tube
64
[2-10] Fastening module, rotating
[2-11] Adapter plate
Unit
2,0 bar– 2,5 bar
3,0 bar – 3,5 bar
6,7 bar – 7,0 bar
7,0 bar – 7,5 bar
10,0 bar
150 Nl/min
740 Nl/min
+5 °C – +60 °C
-20 °C – +60 °C
40 m
66 dB (A)
68 dB (A)
79 dB (A)
69 dB (A)
approx. 541 g
approx. 577 g
max. 10,0 bar

Publicidad

Tabla de contenido
loading

Tabla de contenido