Adjusting the limit stops
IMPORtANt
◆ You have to set limit stops for both directions of travel, UP (▲) / DOWN (▼),
at which the motor turns off.
◆ The tubular motor has been fully installed.
◆ Do not disassemble the mechanical stoppers on the last shutter slat.
◆ The roller shutter box must be open and the set button (11) on the tubular motor
must be easily accessible.
Working with an open roller shutter box is associated with a
STOP
hand- crush hazard.
Never reach into the winding shaft when the motor is running.
Button assignment at the switch setting device (21)
Set button
SEt
Direction of travel (▲/▼)
Adjusting the upper / lower limit stop
1.
2.
oder
SEt
3.
oder
SEt
4.
oder
SEt
Set the switch/control to „raise (▲) / lower (▼)" shutter.
▲
▼
Press the relevant set button* and keep it pressed down until the required limit stop position has been
reached.
The shutter goes up / down.
* on the motor, the switch setting device or the external button
STOP
Release the set button as soon as the shutter has reached the required position.
The motor stops and the upper/lower limit stop position is saved.
The limit stop position can be adjusted in small increments by briefly pressing the set button.
IMPORtANt
If you encounter any problems while adjusting the limit stops, e. g. such as the tubular motor operating for one rotation only even
when pressing the set button, this does not necessarily mean that the motor is defective, but most likely indicates that the adaptor
has slid off the motor head.
Check and, if necessary, adjust the adapter (see page 56).
NOtE
Even after a loss of power, the limit stops remain unaffected.
Initial installation
When installing a shutter and motor for the first time, the roller shutter fitter can
adjust the limit stops with the aid of the set button (11) on the motor or by using
a conventional switch-setting device (21).
Please refer to the switch-setting device's operating instructions for further information.
Changing the limit stops at a later date using external control devices
If, at a later date, you want to change the limit stops of your tubular motor, you
can reset them by using an external button as a set button or your roller shutter
control unit (e.g. Troll Comfort).
IMPORtANt
Do not make the shutter move against the mechanical end stops and keep a safety distance of 2-3 cm.
In case of incorrect rotational direction:
Disconnect the power cable from the mains and change the cores for direction of rotation 1 and 2.
EN
55